1. Overview
AirLive SI-104 User Manual
3
Failed or success in add/remove the node ID can be viewed from Z-Wave
TM
Controller.
Notice 1
: Always RESET a
Z-Wave
TM
device before trying to add it to a
Z-Wave
TM
network.
Notice 2
: When the device into NWI mode, the sensor functionality will useless. The NWI mode will
timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.
1.2 Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in default. When it
wake-
up it will broadcast the “Wake Up Notification” message to the network, and wake-up
10 seconds for receive the setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours.
And the interval step is 30 minutes.
If the user wants to wake-up the device immediately, please press the tamper key once.
The device will wake-up 10 seconds.
1.3 Z-Wave
TM
Message Report
When the smoke sensor detects, the device will report the trigger event and also report the
battery status.
In default the device will using Notification Report to represent the trigger event, it can be
changed to Sensor Binary Report by setting the configuration NO. 7 Bit4 to 1.
1.3.1. Smoke Detected/Test Report
When the Smoke Sensor detects smoke, the device will unsolicited to send the smoke
detected (0x02) report to the nodes in the group 1. When the device is in alarm test mode,
the device will unsolicited to send the Smoke Sensor test (0x03) report to the nodes in the
group 1.
Notification Report (V4)
Notification Type: Smoke (0x01)
Event: Smoke detected, Unknown Location (0x02)
Smoke Alarm Test (0x03)
Sensor Binary Report (V2)