1. Overview
AirLive SI-104 User Manual
4
Sensor Type: Smoke (0x02)
Sensor Value: 0xFF
1.3.2. Tamper Report
When the tamper is pressed, the device will into the alarm state. In that state, if tamper is
released, the yellow LED will light on and the device will unsolicited to send the report to the
nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
Notice :
When the event triggered, the device will report the messages to the nodes in the group 1.
The messages also include the tamper status.
1.4 Power Up Procedure
1.4.1.
NWI
When the device power on, the device will check is it already adding to the network? If
doesn't, press the button to start the NWI mode. Until timeout or the device successful to
inclusion by controller. NWI mode can be aborted by pressing the button 3 times.
1.4.2.
Wake
When the device power on, the device will wake about 20 seconds. In this duration, the
controller can communicate with the device. Normally the device is always sleeping to save
the battery energy.
1.5 Over The Air (OTA) Firmware Update
The device supports the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the button once to start the
update.
Please don't remove the battery
, otherwise it will cause the firmware broken, and the
device will no function.