![Air Live POE-260 CAM User Manual Download Page 50](http://html1.mh-extra.com/html/air-live/poe-260-cam/poe-260-cam_user-manual_2875129050.webp)
7.
Setting
46
AirLive POE-260CAM User’s Manual
7.2.1.3 Periodical Sending
You can set to send an image file to FTP server periodically by selecting
On
to send the
image file to FTP server linked with setting period.
Remote path
:
Type the remote path up to 64 characters.
Image file name
:
Type the file name of the image sent to FTP server up to 10
alphanumeric characters, - (hyphen) and _ (under score).
Suffix
:
Select a suffix to be added to the file name sent to FTP server.
None
:
The name of the sent file will be the Image file name.
Date & time
:
The date & time suffix is added to the Image file name. The date & time
suffix consists of lower two-digits of year (2 digits), month (2 digits), date (2 digits), hour
(2 digits), minute (2 digits) and second (2 digits), and consecutive number (2 digits), thus
14-digit number is added to the file name.
Sequence number
:
A
consecutive
number is added to the Image file name.
Sequence number clear
:
Click
Clear
and the suffix of the sequence number returns to
1.
Interval
:
Set the periodical sending is effective interval. Min value is 1 min and Max
value is 24 hours.
Effective period
:
Set the period when the periodical sending is effective.
Always
:
The periodical sending is always effective.
Schedule
:
You can specify the period when the periodical sending is effective in the
schedule setting in the other section. Click
Schedule
and the setting menu for the
effective period is displayed.