![Air Live POE-260 CAM User Manual Download Page 49](http://html1.mh-extra.com/html/air-live/poe-260-cam/poe-260-cam_user-manual_2875129049.webp)
7.
Setting
AirLive POE-260CAM User’s Manual
45
7.2.1.2 Alarm Sending
Set to forward the image and audio file to the specified FTP server linked with the alarm
detection by the external sensor input or by the built-in motion detection function. Select
On
to send the image and audio file to FTP server linked with the alarm detection.
Remote path
:
Type the path to the destination in FTP server up to 64 characters.
Image file name
:
Type the file name you want to assign to the images when sending to
the FTP server. You can use up to 10 alphanumeric characters, - (hyphen) and _
(underscore) for naming.
Suffix
:
Select a suffix to add to the file name:
Date & time:
The date & time suffix is added to the Image file name. The date/time suffix
consists of lower two-digits of year (2 digits), month (2 digits), date (2 digits), hour (2
digits), minute (2 digits), second (2 digits), and consecutive number (2 digits), thus
14-digit number is added to the file name.
Sequence number:
A consecutive number of 10 digits between 0000000001 and
4294967295 and two fixed digits 00 are added to the Image file name.
Motion Detection
:
Click it on for using
Motion Detection
function as a sensor. You can
set the motion detection function page.
Effective period
:
Set the period when the periodical sending is effective.
Always
:
The periodical sending is always effective.
Schedule
:
You can specify the period when the periodical sending is effective in the
schedule setting in the other section. Click
Schedule
and the setting menu for the
effective period is displayed.