SETUP « B » TIG DIVERS
20
Réglage usine 20A / Setting made by the producer 20A
B1
Courant d’amorçage TIG PAC
TIG PAC arc ignition current
3…230
Ajustable de 3 à 230A / Adjustable from 3 to 230A
1.0
Réglage usine 1S / Setting factory 1S
B2
Durée de haute fréquence d’amorçage HF
HF high frequency arc ignition time
0.2…2.0
Ajustable de 0,1 à 2S / Adjustable from 0,1 to 2S
10
Réglage usine 10% du courant de soudage
Setting made by the producer: 10% of welding current
B3
Arrêt « naturel » de l’arc pendant l’évanouissement
« Natural » extinguishing of the arc during turning off the arc
5…10
Ajustable de 5 à 40% du courant de soudage
Adjustable from 5 to 40% of welding current
OFF
Réglage usine /
Setting made by the producer
PAN
Réglage usine et mémorisation des programmes
Setting made by the producer and memorising of programmes
B5
Réglages usines / Setting made by the producer
ALL
Réglage usine et RAZ des programmes
Setting made by the producer and resetting of programmes
1
Même vitesse que A10 (limitation du temps de montée)
The same speed as A10 (limitation of the period of increase)
2
En fonction des paramètres d’évanouissement
Depending on parameters of extinguishing
B6
Méthodes d’évanouissement
Method of extinguishing
3
Pas d’évanouissement / The arc has not been extinguished
OFF
Réglage usine / Settings made by the producer
B7
Evanouissement non linéaire /
Non – linear extinguishing
0…50
Ajustable 0…50% du courant de soudage
Adjustable 0…50% of welding current
0.4
Réglage usine 0,4s /
Settings made by the producer 0,4s
B8
Temps de gâchette (citostep pu 4T level)
Time of pushing of welding gun trigger (citostep or 4T level)
0.3…1.0
Ajustable 0,3…1,0s / Adjustable 0,3…1,0s
OFF
Réglage usine 4mn / Settings made by the producer 4mn
B9
Arrêt groupe de refroidissement après soudage
Turning off the cooling system after welding
ON
Réglage 30s / Settings
30s
OFF
Réglage usine 0,0…15,0s – pas 0,1s / Settings made by the
producer 0,0…15,0s – step 0,1s
B10
Sélection « calibre » temps de point
Selection « calibre » time required for obtaining of the required
point
ON
Ou 0…150s – pas 1s
Or 0…150s – step 1s
0
Réglage usine / Settings made by the producer
B11
MMA : Arc Force
-9…0…9
Ajustable -9 = soft arc, 9 = rough arc /
Adjustable -9 = soft arc, 9 = rough arc
0
Réglage usine / Settings made by the producer
B12
Courant de démarrage MMA (Hot Start)
Starting current MMA (Hot Start)
-9…0…9
Ajustable -9 = minimum overrun, 9 = maximum overrun
Adjustable -9 = minimum overrun, 9 = maximum overrun
10
Réglage usine 10% du courant de soudage
Setting made by the producer: 10% of welding current
B13
Courant de démarrage TIG (Hot Start)
Starting current TIG (Hot Start)
OFF
Courant minimum / Minimum current
5…40
Ajustable de 5 à 40% du courant de soudage
Adjustable from 5 to 40% of welding current
5.0
Réglage usine 5,0s / Setting made by the producer 5,0s
B14
Temps d’affichage des paramètres
Time of displaying of parameters
1.0…20.0
Ajustable de 1,0 à 20,0s / Adjustable from 1,0 to 20,0s
1.0
Réglage usine 1,0s / Setting made by the producer 1,0s
B15
Cycle 2T : Temps de Hot Start (courant de démarrage)
2T Cycle: Hot Start time (starting current)
0.1…5.0
Ajustable de 1,0 à 5,0s / Adjustable from 1,0 to 5,0s
SETUP « C » et « D » (Mini / Maxi)
0.0
Réglage usine 0,0s / Setting made by the producer 0,0s
C1
Temps de prégaz minimum
Minimum pre – gas time
0.0…2.0
Ajustable de 0 à 2s / Adjustable from 0 to 2s
1.0
Réglage usine 1,0s / Setting made by the producer 1,0s
C7
Temps de postgaz minimum
Minimum post – gas time
0…10
Ajustable de 0 à 10s / Adjustable from 0 to 10s
-80
Réglage usine -80% / Setting made by the producer -80%
C16
Réglage balance minimum
Setting of minimum balance
-80…-10
Ajustable de -80% à -10% / Adjustable from -80% to -10%
1
Réglage usine 1s / Setting made by the producer 1s
D1
Temps de prégaz maximum
Maximum pre – gas time
0…10
Ajustable de 0 à 10s / Adjustable from 0 to 10s
30
Réglage usine 30s / Setting made by the producer 30s
D7
Temps de postgaz maximum
Maximum post – gas time
15…150
Ajustable de 15 à 150s / Adjustable from 15 to 150s
10
Réglage usine 10% / Setting made by the producer 10%
D16
Réglage balance maximum
Setting of maximum balance
0…20
Ajustable de 0 à 120% / Adjustable from 0 to 120%
SETUP « E » Mode AC et MIX
60
Réglage usine 60 Hz / Setting made by the producer 60 Hz
E1
Fréquence en mode AC
Frequency in the AC mode
50…250
Ajustable de 50 à 250 Hz / Adjustable from 50 to 250 Hz
Sqr
Signal carré
E2
Forme du signal AC
Form of the AC signal
Sin
Forme sinusoidale
5
Réglage usine 5 A / Setting made by the producer 5 A
E3
Composante continu du signal AC
Single – direction component of the AC signal
5…20
Ajustable de 5 à 20 A / Adjustable from 5 to 20 A
-25
Réglage usine -25 % / Setting made by the producer -25 %
E4
Balance par défaut
Default setting of balance
-50…10
Ajustable de -50 à 10 % / Adjustable from -50 to 10 %
100
Réglage usine 100 % / Setting made by the producer 100 %
E5
Première alternance négative en mode AC
The first negative alternation at AC mode
100…500
Ajustable de 100 à 500 % (Max 240 A) /
Adjustable from 100 to 500 % (Max 240 A)
Summary of Contents for SAF-FRO PRESTOTIG 240 AC/DC
Page 112: ...112 D3 PIECES DE RECHANGE COOLERTIG 2 D3 6 5 18 4 19 3 2 20 8 11 12 1 16 9 10 17 7 13 14 15 ...
Page 113: ...113 SCHEMA PRESTOTIG 240 AC DC ...
Page 114: ...114 D3 PIECES DE RECHANGE PRESTOTIG 310 AC DC D3 14 6 12 3 1 17 2 7 15 4 under 13 16 33 9 ...
Page 116: ...116 SCHEMA PRESTOTIG 310 AC DC P R E S T O T I G 3 1 0 A C D C ...
Page 117: ...117 DESCRIPTION DU PANNEAU DE REGLAGE DU PRESTOTIG 240 310 AC DC voir page 6 ...
Page 118: ...118 DESCRIPTION DU PANNEAU DE REGLAGE voir page 6 ...
Page 119: ......
Page 120: ......
Page 121: ......