Page
25
of
125
TC_AM Torque
Control
Angle
Monitor Stage
Control
strategy is convenient for detection of cross
threaded or stripped fasteners. Rundown is considered to
be successful (Accept) if the stage peak torque value
falls within range specified by
Torque High Limit
and
Torque
Low Limit
and final angle value falls within the
range specified by
Angle High Limit
and
Angle Low Limit
parameters.
Torque High:
Upper control limit of the rundown.
Torque Target:
Final desired torque.
Torque Low:
The lower control limit of the rundown.
Angle Bailout:
Determines when to stop the tool on angle
during any Torque Control strategy. Should be set equal
to or above High Angle. Units are degrees of rotation.
Angle High:
Maximum acceptable angle rotation in
degrees.
Angle Low:
Minimum acceptable angle rotation in
degrees.
Reference Torque:
(drop down menu)
Overall Angle:
Angle is measured starting from
lever/trigger
pull.
In-cycle Angle:
Angle is measured from In-Cycle
torque
value (Determined in PSet screen).
Stage Angle:
Angle is measured from Reference
Torque.
Reference Torque:
If Stage Angle is selected, this will be
the start point (in Torque) at which angle is monitored.
NOTE:
Set Reference Torque to zero to measure Stage
Angle from the beginning of the stage.
Max (RPM):
Tool Output speed target.
Acceleration(kRPM/s):
How quickly the tool will change speed. The lower the value the slower
the accleration ( Glossary for detailed description).
Stage Timeout:
Maximum allowable time in this stage. If time is exceeded, the tool will stop and
the Rundown will be terminated.
TC AM Stage