Doc
No.
FM5640
issue
3
Page
32
17.
IP
‐
DECT
6500
SYSTEM
INSTALLATION
16 PORT ETHERNET SWITCH CONNECTIONS
The
16
Port
Ethernet
Switch
provides
8
PoE
Ports
(Power
over
Ethernet)
for
the
IP
‐
DECT
Base
Stations.
POWER
‐
connect
to
a
battery
backed
output
on
the
UPS
via
the
in
‐
line
PSU
module
provided.
PORTS
1
to
8
‐
connect
to
the
IP
‐
DECT
base
stations
using
up
to
100
metres
of
4
pair
Cat5e
cable.
PORTS
9
to
16
‐
connect
to
the
IP
‐
DECT
Server
6500,
optional
Integrator/IP
‐
PBX
using
RJ45
patch
leads.
Note;
a
second
16
Port
Ethernet
Switch
(8
x
PoE)
can
be
connected
to
increase
the
number
of
IP
‐
DECT
base
stations
to
16.
Connect
the
second
Ethernet
Switch
to
the
UPS
and
link
the
2
units
via
a
Patch
Lead
between
a
spare
Port
9
to
16.
Alternatively,
a
24
PoE
Port
Ethernet
Switch
is
available
–
Tynetec
Part
No.
ZXT559.
IP-DECT SERVER 6500 PROGRAMMING
The
IP
‐
DECT
Server
6500
must
have
its
IP
address
set
to
192.168.0.3.
Refer
to
the
manufacturers
installation
guide
for
full
instructions
–
see
section
6
of
this
manual.
IP-DECT BASE STATION PROGRAMMING
IP
‐
DECT
Base
Station
IP
addresses
must
start
at
192.168.0.4
with
RPN
4
and
carry
on
sequentially.
Refer
to
the
manufacturers
installation
guide
for
full
instructions
–
see
section
6
of
this
manual.
4 CHANNEL MULTI CELL REPEATERS
A
maximum
of
three
4
Channel
Multi
‐
Cell
Repeaters
can
be
connected
per
IP
‐
DECT
Base
Station.
Repeaters
require
a
power
connection
only;
they
communicate
with
the
Base
Station
via
low
power
radio
signals
and
do
not
require
a
line
connection.
To
maintain
DECT
coverage
during
a
mains
failure
all
Repeaters
must
be
connected
to
a
battery
backed
12V
DC
PSU.
REPEATER POSITIONING
Before
installing
power
cables
to
Repeater
positions,
it
is
important
that
the
optimum
position
for
coverage
is
established.
Register
the
Repeater
onto
the
IP
‐
DECT
Base
then
with
the
Repeater
powered
from
a
battery
walk
away
in
the
direction
that
cover
is
to
be
extended.
When
the
red
LED
on
the
Repeater
starts
to
flash
it
is
out
of
range
and
must
be
moved
back
towards
the
IP
‐
DECT
Base
by
a
minimum
of
5
metres
before
selecting
its
final
location.
The
LED
should
be
steady
green.
See
Repeater
Deployment
Rules
on
the
following
page.
REPEATER PROGRAMMING
Refer
to
the
manufacturers
installation
guide
for
full
instructions
–
see
section
6.
A
programming
kit
(P/No.
ZCS729)
is
required
to
program
Repeaters,
the
Service
Tool
software
can
be
downloaded
via
the
link
in
section
6
of
this
manual.
REPEATER POWER CONNECTION
Repeaters
should
be
connected
using
8
core
cables;
cores
can
be
doubled
‐
up
and/or
looped
back
to
form
a
ring
circuit
to
reduce
the
voltage
drop
if
necessary.
4
Channel
Multi
‐
Cell
Repeaters
(3
per
IP
‐
DECT
Base
Station)
240V
AC
Battery
Backed
12V
DC
PSU
Repeater
Power
Lead
Colour
Code
YELLOW
=
12V
BLACK
=
0V
Use
8
Core
Cable
Max
100m