Doc
No.
FM5640
issue
3
Page
16
13.
DECT
REPEATER
BATTERY
BACKED
PSU
The
12V
DC
2A
battery
backed
PSU
(Aidcall
Part
No.
E40062)
requires
connection
to
the
mains
supply
via
an
un
‐
switched
13A
socket.
INSTALLATION
Undo
the
lid
fixing
screw
and
open
the
lid.
Note:
if
the
lid
is
removed
ensure
the
Safety
Earth
is
re
‐
connected.
Position
the
PSU
within
2
metres
of
an
un
‐
switched
13A
mains
socket.
Fix
the
power
supply
unit
to
the
wall
using
the
3
holes
“
A
”
as
shown
below.
Connect
the
mains
lead
provided
to
the
power
supply
unit
mains
terminals
using
the
colour
code
in
the
table
alongside.
Note:
the
mains
plug
is
fitted
with
a
240V
AC
5A
BS1362
fuse.
PSU FIXING
The
PSU
should
only
be
opened
during
installation
and
service
–
the
lid
must
be
screwed
shut
at
all
other
times
to
prevent
the
risk
of
electric
shock.
Never
leave
a
live
PSU
unattended
with
the
lid
open.
Wall
Mounted
Enclosure
200
x
230
x
80mm
(HxWxD)
2m
Mains
Lead
&
13A
UK
Plug
Green
Power
LED
Red
Fault
LED
12V
DC
2A
PSU
Hinged/Removable
Lid
Mains
Connection
Colour
Terminal
Brown
L
Blue
N
Green
/
Yellow
E
160mm
65mm
145mm
A
A
A
12V/1A Boxed PSU
E
N
L
O/P
+
‐
PSU LED INDICATORS
The
GREEN
POWER
LED
should
be
permanently
illuminated
when
the
Mains
Supply
is
healthy.
The
RED
FAULT
LED
will
illuminate
if
the
12V
output
fuse
has
blown
or
the
battery
PTC
resettable
fuse
has
tripped.
95mm
Battery
Backed
12V/2A
Boxed
PSU