Doc
No.
FM5640
issue
3
Page
21
15.
IP
‐
DECT
400
SINGLE
‐
CELL
SYSTEM
INSTALLATION
The
IP
‐
DECT
Server
400
single
‐
cell
option
is
suitable
for
small
installations
using
1
Server/Base
Station
and
up
to
6
Repeaters.
Up
to
12
DECT
handsets
can
be
used
on
a
single
‐
cell
system.
Part
No.
Description
Notes
ZXT503
IP
‐
DECT
Server 400 (Single
‐
Cell)
1
per
site
ZXT512
2
Channel
Multi
‐
Cell
Repeater
max
6
per
site
ZXT526
7722
DECT
Handset inc Charger &
PSU
max
12 per
site
W07485
5
Port
Ethernet Switch
1
per
site
ZXT502
PoE
Injector
1
per
site
ZXT548
700VA
UPS
1
per
site
E40062
12V/2A
Battery
Backed
PSU
1
per
site
W03076
Integrator
1
per
site
(optional)
W03220
‐
25
Matrix
PE
IP
‐
PBX
1
per
site (optional)
UPS CONNECTION
To
maintain
DECT
operation
during
a
mains
failure
the
Ethernet
Switch,
PoE
Injector
and
optional
Integrator/IP
‐
PBX
must
be
powered
from
the
battery
backed
output
sockets
on
the
UPS.
PoE INJECTOR CONNECTION
The
PoE
injector
provides
Power
over
Ethernet
for
the
IP
‐
DECT
Server
400
(Single
‐
Cell).
POWER
‐
connect
to
a
battery
backed
output
socket
on
the
UPS
using
the
mains
lead
provided.
ETHERNET
‐
connect
to
the
Ethernet
Switch
using
an
RJ45
patch
lead.
ETHERNET
&
PoE
‐
connect
to
the
IP
‐
DECT
Server
400
using
an
RJ45
patch
lead.
This
connection
can
be
extended
to
a
maximum
of
100
metres
using
Cat5e
cable.
5 PORT ETHERNET SWITCH CONNECTIONS
POWER
‐
connect
to
a
battery
backed
output
socket
on
the
UPS
using
the
mains
lead
provided.
ETHERNET
PORTS
‐
connect
to
the
PoE
Injector
and
optional
Integrator/IP
‐
PBX
using
RJ45
patch
leads.
DECT
Handsets
(max
12)
IP
‐
DECT
Server
400
(Single
‐
Cell)
2
Channel
Multi
‐
Cell
Repeaters
240V
AC
240V
AC
Battery
Backed
PSU
PoE
Injector
Optional
Integrator
Repeaters
(max
6)
700VA
UPS
Touchsafe
Pro
Nursecall
Panel
5
Port
Ethernet
Switch
Optional
IP
‐
PBX
Ext
Lines