14.
INTEGRATOR
&
PSU
TOUCHSAFE PRO PANEL CONNECTION
Cut
an
RJ45
plug
off
one
end
of
the
Cat5e
Patch
lead
and
loop
the
wire
through
a
ferrite
sleeve
provided
with
the
Touchsafe
Pro
panel.
Strip
‐
back
the
insulation
and
connect
the
white/green,
orange
and
white/blue
cores
to
the
Touchsafe
Pro
panel
PAGER
terminals
as
shown
below;
Note:
the
data
lead
can
be
extended
up
to
a
maximum
of
20
metres
using
LSF
(Low
Smoke
and
Fume)
screened
TCCA
8
core
alarm
cable.
This
cable
is
available
from
Aidcall
by
the
metre;
Part
No.
YW1730.
Configure
the
9
Pin
D
‐
Sub
Female/RJ45
Adapter
using
the
colour
code
in
the
table
below;
Plug
the
Patch
Lead
into
9
Pin
D
‐
Sub
Female/RJ45
Adapter,
then
plug
the
D
‐
plug
into
the
Integrator
Serial
Port
B.
Setup
the
Touchsafe
Pro
panel
as
described
below.
9
Pin
D
Pin
No.
Adapter
Wire
Colour
RJ45
Pin
No.
Cat5e
Wire
Colour
2
White
2
Orange
3
Yellow
3
White/Green
5
Blue
5
White/Blue
Maximum
20m cable
length
between
Panel
and
Integrator
IMPORTANT
Loop
the
wire
once
through
a
Ferrite
Sleeve
provided
with
the
Panel
Touchsafe
Pro
Pager
Port
Plug
into
Integrator
Serial
Port
B
Cat5e
Patch
Lead
9
Pin
D
‐
Sub
Female/RJ45
Adapter