Doc
No.
FM5640
issue
3
Page
17
13.
DECT
REPEATER
BATTERY
BACKED
PSU
BATTERY REPLACEMENT
The
12V
DC
2A
power
supply
unit
provided
for
the
Repeaters
includes
a
12V
3.4Ah
rechargeable
battery.
This
battery
will
maintain
normal
operation
for
several
hours
in
the
event
of
a
mains
power
failure.
The
rechargeable
battery
should
be
removed
and
tested
by
a
Service
Engineer
on
an
annual
basis
and
replaced
every
3
‐
5
years.
With
the
battery
disconnected;
check
the
charge
voltage
across
the
battery
leads
is
between
13.6V
DC
and
14.2V
DC
(13.8V
nominal).
If
the
battery
shows
any
signs
of
damage,
swelling
or
leakage
during
an
annual
inspection
it
should
be
replaced
immediately.
Only
replace
with
the
Manufacturers
Approved
battery
type:
Yuasa
NP3.4
‐
12:
12V
3.4Ah
Sealed
Lead
Acid
Rechargeable
Battery
Replacement
batteries
are
available
from
Aidcall;
order
Part
No.
F00040
IMPORTANT:
always
mark
the
battery
with
the
date
it
was
replaced
for
reference
on
future
Service
visits.
See
section
3
of
this
manual
for
Regulations
regarding
the
safe
disposal
of
used
batteries.
12V
DC
2A
Power
Supply
12V
3.4Ah
Lead
Acid
Rechargeable
Battery