Version April 2008
10
EN
agru SP 315-S User’s Manual
3.2.3 Ports and Switches
3.2.4 Specifications
agru SP 315-S
Power Supply Characteristics
Voltage
Frequency
Total Rated Power
Heating Element Power
Facing Tool Power
400 V AC ± 10%
50/60 Hz
13 kW
9 kW
1.1 kW
Welding Operation Specs
Welding Force
Speed of Facing Tool
Ambient Temperature (operation)
Ambient Temperature (storage)
Operating Range
3500 N
23 rpm
+0°C to +40°C (32°F to 104°F)
–5°C to +50°C (23°F to 122°F)
110 - 315 mm (4-3/4" - 12-1/2")
Dimensions and Weight
Dimensions (W x D x H)
Machine in transport box, w/o support legs
Machine only, excluding printer
bracket and support legs
Weight
Maximum Carriage Stroke
1400 x 1700 x 1070 mm (4' 4" x 5' 7" x 3' 6")
1045 x 1580 x 1310 mm (3' 5" x 5' 2" x 4' 3-1/2")
approx. 1100 kg
268 mm (10-1/2")
Important
The power supply connection is designed as a 3-phase plus
ear th ground connection. No neutral conductor is needed.
The power supply connection should be rated at 32 amps and
should be wired with an automatic safety switch of 32 amps
medium-slow blow. The conductor section of the power supply
connection should be minimum 4 sq. mm.
Important
For the connection to mains power an approved CEE plus and
outlet have to be used and wired according to the specifica-
tions quoted above. Compare also the photograph as well as
its legend and explanations below.
Nitrogen Control
Fuse of Nitrogen
Control
Power Supply to Printer
Buzzer
Scanning Pen
On/Off Switch
Ambient Temperature Sensor
USB B Interface
(for connection to PC)
USB A Interface
(for connection to tag printer or a
USB stick)
Scanning Pen Port