29
3 Batch count:
-
First batch is 2 packets and 50 seed/packet
-
Second batch is 8 packets and 39 seed/packet
-
Last batch is 9 packets and 66 seeds/packet
The residual number is 55. If the batch number increases to 1 the number of data
field in the output data will increase to 2. The number of the data fields in the
example3 is 8
6.1.4 Specific codes (ASCII code)
End Code: ASCII Decimal 10 (Line Feed), 12(Carriage Return)
ASCII Hex 0A(Line Feed), 0D(Carriage Return)
Delimiter Code: ASCII decimal 44 (,)
ASCII Hex 2C (,)
6.2 Communication setup
Set-up COM port
-
Baud rate: 9600.
-
Odd parity
-
Parity on
-
1 stop bit
-
7 data bits
-
None flow control
-
Set default mode for the size of input buffer or output buffer
6.3 Collect data from ESC2
(without a query)
If a laptop or mobile device is connected to ESC2 counter and a third party software is
properly setup, you can send data out from the counter by just pressing
‘button 7’
in the
counter’s control box in totalize mode and by pressing
‘button 6’
in batch count mode.
6.4 Collect data from ESC2
(with a query)
In this case the assumption is that you have your own software or a third party software
that can send a query to the counter.
The only thing that you need to do is to send
‘CQY’
to
‘ESC2’
then you can get data
required from ESC2. If you want to clear the count number that appeared on the Control
Box display panel, you can send it to
‘CLR’
to clear it. See example below:
-
Data format: CQY
-
Clear Data: CLR
6.5 Configure WinWedge
(without sending out a query)