Commissioning and Operation
Hydrostatic implement carrier agria 5900 Cyclone
41
Starting the petrol engine
1. Depending on the version, open one or both
fuel cock(s) (C/13)
2.
Cold
engine: Set CHOKE actuator (C/20) to
"CHOKE". Reset CHOKE when the engine is
hot
Engine
at operating temperature
: Leave
CHOKE in normal operating position
3. Set speed regulating lever (B/9) to approxi-
mately 1/3 throttle
4. Insert the ignition key into the ignition lock
(B/12) and turn it clockwise to position "
I
" -
even if you start the engine with cable-pull
starter
- Warning lamp lights (Yamaha)
5. Start the engine from outside the hazard
zone:
- Continue turning the ignition key clockwise
to "START" position
As soon as the engine starts, release the ignition
key. The key returns automatically to position "
I
",
and the warning light goes out.
If the engine does not start, turn the ignition key
back to position "
O
" before you try again to start
(start repetition lock).
- Or manual start with cable-pull starter
Tow-start is not permitted!
6. Once the engine is running, allow the engine
to warm up for a short time. Slowly move the
choke actuator back to operating position (if
actuated).
When the petrol engine is running, do not
touch or remove the ignition cable or spark
plug connector.
Summary of Contents for Cyclone 5900
Page 4: ...4 agria 5900 Cyclone Designation of parts Fig A Fig B...
Page 22: ...2 Technical Data 22 Hydrostatic implement carrier agria 5900 Cyclone...
Page 80: ...80 Hydrostatic implement carrier agria 5900 Cyclone Petrol engine 23 HP...
Page 83: ...Hydrostatic implement carrier agria 5900 Cyclone 83 Declaration of Conformity...
Page 85: ...agria 5900 Cyclone 85 Fig C Petrol engine 14 HP...
Page 87: ...agria 5900 Cyclone 87 Fig D Petrol engine 23 HP...