![Agilent Technologies OmniBER OTN J7230B Performance Verification Manual Download Page 88](http://html1.mh-extra.com/html/agilent-technologies/omniber-otn-j7230b/omniber-otn-j7230b_performance-verification-manual_2868192088.webp)
Performance Tests
1
Verification Manual
85
3
Press
<Menu>
, select
Tx/Rx > Transmitter settings
and set
the
Signal Mode
to
SDH
. Now set the
Signal Rate
to
STM-1,
and
Interface
to
Electrical
.
4
Load the
155Mb_ITU_0.msk
test mask and check the ‘zero’
pulses are within the mask. See examples.
5
Also check the ‘ones’ pulses (normal & inverted) by loading
and checking against the
155Mb_ITU_1.msk
and
155_ITU_1_INV.msk
test masks (see examples).
STM-1 All Zeros Mask Test
Verification.book Page 85 Monday, January 19, 2004 1:40 PM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com