17
Technical Information
Optional Serial Port
Command: ERR-CODE
Source: PC
Destination: Inverter
02 80
32 30 36 30 03 38 37
STX ADDR WINDOW
RD ETX CRC
Source: Inverter
Destination: PC
02 80 32 30 36 30 30 30 30 30 30 30 03 38 37
STX ADD WINDOW
RD 000000
ETX CRC
NOTE
Using the RS 485 interface, the message structure remains identical to the one
used for the RS 232/422 interface, the only difference being that the value
assigned to the ADDRESS <ADDR> field in this case can be any hex value,
while for the RS 232/422 this value must be set to 80 hex.