Maintenance 59
4510012 - REV F – 220621
Apply Teflon paste to both sides of the new Heating Element Gasket and use it to
replace the old Heating Element Gasket.
With the new Gasket in place, install the freshly cleaned Heat Element back onto the
Boiler Tank and secure it with the six Bolts.
Reconnect the Conductor Wires to the Conductor, referring to rewiring notes taken
during disassembly to ensure original wiring configuration.
WARNING:
Electrical Shock Hazard. Be sure that Conductors and
Conductor Wires are dry before reconnecting.
WARNING:
Failure to
reconnect the Conductors and Conductor Wires in
their original configuration will result in a short in the Boiler system and
damage to the Boiler Controls and other components.
If needed, see the Boiler Owner’s Guide (included) for additional location of parts.
Reinstall the Electrical Cabinet Front Panel.
AFM-4510012-00076-01
Inside of a Boiler that has not been Cleaned Out for a Year
Summary of Contents for STC-WSN300-2M
Page 1: ...WSN GEN S Steam Heat Shrink Tunnel User Guide ...
Page 2: ...2 Abbreviations 4510012 REV F 220621 ...
Page 8: ...8 Abbreviations 4510012 REV F 220621 ...
Page 66: ...66 Troubleshooting 4510012 REV F 220621 ...
Page 67: ...Electrical Schematics 67 4510012 REV F 220621 Electrical Schematics Complete System WSN GEN S ...
Page 68: ...68 Electrical Schematics 4510012 REV F 220621 Boiler ...
Page 72: ...72 Parts List 4510012 REV F 220621 Exploded Diagrams Stand Drawing Number YS130EX2 01 ...
Page 74: ...74 Parts List 4510012 REV F 220621 Tunnel Drawing Number YS130EX2 02 ...
Page 78: ...78 Parts List 4510012 REV F 220621 Boiler ...
Page 79: ...Parts List 79 4510012 REV F 220621 Inside Boiler Electrical Cabinet ...