Maintenance 55
4510012 - REV F – 220621
Open the Blowdown Valve slowly by turning the handle until valve is fully opened
(parallel to the line) for approximately 3 seconds, and then turn the handle back to the
closed position (perpendicular to the line).
Repeat this process of opening and closing the Blowdown Valve until the water level
reaches the bottom of the Sight Glass.
When water discharge is complete, completely close the Blowdown Valve (perpendicular
to the line).
Detach the Blowdown Hose.
Blowdown is complete.
Blowdown Valve
(Closed)
AFM-4510012-00038-01
AFM-4510012-00044-01
Blowdown Valve
(Open)
Sight
Glass
AFM-4510012-00052-01
Boiler Water Level
Drain Level
Blowdown Valve
(Closed)
AFM-4510012-00038-01