2.7. SAFETY WARNING FOR ELECTRICAL EQUIPMENT
The electrical system has been designed and built in compliance with applicable legislation.
This legislation also specifies the ambient conditions required for operation.
The following list specifies ambient conditions necessary to ensure correct electrical system function.
―
Ambient temperature must be between
5°C
°C and
40°C
.
―
Relative humidity must be between
50%
(measured at
40°C
) and
90%
(measured at
20°C
).
―
The installation area must not be subject to or contain sources of electromagnetic interference or
radiation (X rays, laser light etc).
―
The installation area must not contain potentially explosive or flammable mixtures of gases or dust.
―
No contaminant or corrosive products (acids, chemicals, salts etc.) may be used during production and
maintenance. Any products used must be kept away from electrical components.
―
The ambient temperature during storage must be between
- 25°C
and
55°C
.
―
Electrical equipment may be exposed to temperatures up
70°C
, provided that exposure does not
exceed
24
hours.
―
The electrical system will function correctly up to an altitude of
1000 m
above sea level.
If any of the aforementioned conditions cannot be met, any additional measures necessary to
ensure safe operating conditions (e.g. special electrical components, air conditioning systems
etc.) must be defined during the contractual stage.