![Aeroflex Gaisler RT-SPW-ROUTER User Manual Download Page 46](http://html1.mh-extra.com/html/aeroflex-gaisler/rt-spw-router/rt-spw-router_user-manual_2862505046.webp)
AEROFLEX GAISLER
46
RT-SPW-ROUTER
Copyright Aeroflex Gaisler AB
June 2012, Version 1.2
0
1
1
0
0
1
Write, incre-
menting
address, do
not verify
before writ-
ing, no
acknowledge
Not implemented. Packet is dis-
carded and no reply is sent.
0
1
1
0
1
0
Write, sin-
gle-address,
do not verify
before writ-
ing, send
acknowledge
Not implemented. Command is
not executed. Error code is set to
10 and a Reply is sent.
0
1
1
0
1
1
Write, incre-
menting
address, do
not verify
before writ-
ing, send
acknowledge
Not implemented. Command is
not executed. Error code is set to
10 and a Reply is sent.
0
1
1
1
0
0
Write, single
address, ver-
ify before
writing, no
acknowledge
Supported. Length must be 4,
address must be word aligned
and within the allowed range.
Otherwise the command is not
executed. No reply is sent.
Table 32. RMAP command support by the configuration port.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Packet type
Action
Reserved
Command
/ Response
Write /
Read
Verify
data
before
write
Acknow-
ledge
Increment
Address