![Aerco G-13-1854 Installation, Operation And Maintenance Manual Download Page 73](http://html.mh-extra.com/html/aerco/g-13-1854/g-13-1854_installation-operation-and-maintenance-manual_2861565073.webp)
Innovation Water Heaters Installation, Operation & Maintenance Manual
CHAPTER 6 – MAINTENANCE
OMM-0078_0J
AERCO International, Inc.
•
100 Oritani Dr.
•
Blauvelt, NY 10913
Page
73
of
196
GF-128
Phone: 800-526-0288
PRI: 11/22/2013
Igniter Inspection/Replacement –
Continued
NOTE
If a replacement igniter is being installed, clocking (indexing) washers will be
included with the replacement part. These washers may be needed to
properly position the ground tab of the igniter to ensure that it is pointing
outward toward the perimeter of the intake manifold flange.
7. Refer to Figure 6-2 and reinstall the igniter on the intake manifold flange. Install clocking
washers as needed, to ensure that the igniter ground tab is pointing outward toward the
perimeter of the intake manifold flange. Torque to 15 ft-lbs. Do not over tighten.
8.
Figure 6-2. Igniter & Flame Detector Mounting Details
9. Reconnect the igniter cable and ground wire.
10. Reinstall the side and rear panels on the unit.
BLOWER SIDE
INTAKE
MANIFOLD
IGNITOR
FLAME
DETECTOR
OBSERVATION
PORT
MOUNTING
SCREWS
FLAME
DETECTOR
GASKET
IGNITOR