THE AUDIBLE NOTIFICATIONS

14

SUMMARY OF THE VISUAL AND AUDIBLE NOTIFICATIONS

NOTIFICATIONS

Exit And Entry Beeps

NOTE:

Warning beeps

!

!
!

!

!

!

!

Short beeps at 0.5 second interval
Increase to 4 beeps/second at the last 10

seconds, then
One long beep to indicate the end of the

delay period

Short beeps at 0.5 second interval
Increase to 4 beeps/second at the last 10

seconds, then
One long beep to indicate the end of the

period

The beep stops at anytime when manual battery

test starts or when system is set to programming

mode with the system code (HA-263D)

4 fast beeps at 1 second interval

2 Short beeps

1 Short beep/30 seconds

5 Short beeps first, then

1 Short beep/30 seconds

EVENTS

System in Exit Delay Period

OR

System in Entry Delay Period

System in Standby Mode Period

System is or was in Alarm condition

(Alarm occurred)

Successful Key-switch operation

OR

Battery is Normal after Testing

AC power Failure

Battery Low After Testing

HA-263

15

OPEN THE CABINET FOR SERVICE

GENERAL SPECIFICATIONS

The HA-263K is protected by a built-in tamper switch. Opening of the cabinet will trigger the

tamper switch to give alarm.
If opening of the cabinet for service is required, it is necessary to set the system to standby

mode by holding the keyswitch in contact for 5 seconds (ignore the 2 arming beeps). The

standby mode lasts for 1 minute and the system gives no function including the tamper switch

during the period. Setting the system to standby mode can only be done while all the partitions

are in disarmed mode without alarm memory existing.

!

!

!

!

!

!

!

!

!

!

!

!

!

Power Source

: 16.5V AC

Back-up Battery Requirement

: 6.5-7.0Ah, 12V Rechargeable sealed lead acid - not

included

(Built-in Charger in system)

Temperature Range

: 0 Deg C to +65 Deg C

Standby Current

: 100mA Typical

Protection Zones

: 8 Protection zones in 3+3+2 partitions

Control Station

: Key-switches and/or Digital keypads, 4 maximum

Entry Delay

: 15-90 Seconds

Exit Delay

: 60 Seconds

Alarm Duration

: 3-15 Minutes, or

Power Up Delay (Standby Mode): 60 Seconds
Audible Beeps

: Entry, Exit & Alarm Warning, ON-OFF programmable

G. Weight

: 2.5 Kgs (one Master unit & one Control Station)

Dimensions

: Master unit: 265(W) X 270(H) X 78(D) mm

Key-switch: 73(W) X 117(H) X 43(D) mm
Digital Keypad: 117(W) X 117(H) X 27(D) mm

4

HA-263

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...

Reviews: