HA-263D

GENERAL DESCRIPTION

THE DIGITAL CONTROL KEYPAD

HA-263K owner requires no study of this section. All information is for HA-263D only.

HA-263D is the version comes with a digital control keypad which allows owner to program two

independent user codes for partition 1, 2 and the common partition; and also one user code for

the whole system in arm-disarm control. Apart from that the system also gives the following

Additional features:

Set up Master Code for programming authorization.
Software panic button -- press any two buttons simultaneously for more than 3 seconds to

give alarm.
Make bypass to the un-used zone(s) and the faulty zone(s).
Put the habitually bypassed zone(s) in memory for HOME mode.
Make system to show the faulty zone(s) during disarmed condition with user code.
Make system to arm instantly without delay.
Clear the alarm memory in the specific partitions or in the whole system.
Initiate dynamic battery test at anytime during disarmed mode.
Initiate a 5-second operation of both timing and latch output relays to test the connected

siren and strobe light.
System Code for Direct Access to Programming mode in case of the Master Code is forgotten.

The "System Setting Jumper" on the main circuit board MUST be set on "DK" Position for keypad

only or  keyswitch operation.

1)
2)

3)
4)
5)
6)
7)
8)
9)

10)

16

SYSTEM

HA-263

13

SUMMARY OF THE VISUAL AND AUDIBLE NOTIFICATIONS

THE ZONE STATUS LEDS FOR PARTITION 1 AND 2

THE SYSTEM STATUS LED (SHOWING THE SYSTEM STATUS ALL THE TIME)

INDICATIONS

ON

2 Flashes with one

second pause

3 Flashes with one

second pause

Flash

Flashes Alternatively with

Zone Status LEDs

EVENTS

AC power and battery power normal
AC power failure

Battery Low

Battery under testing
System in Standby mode

NOTE:

F
F

F

The Zone Status LED of the later turned-on partition also shows the status of the Common

zones. As the common partition follows the later partition to arm.
The alarm indication of zone 7 goes to the later armed partition
The alarm indication of zone 8 (24 hour) goes to both partitions.

INDICATIONS

OFF

ON

Flash

2 Short Flashes/Second

Fast Flashes

3 Short Flashes/Second

ON

Flashes Alternatively with

System Status LED

4

HA-263

EVENTS

System disarmed
Zone abnormal during Exit Delay Period, check the circuit loop

immediately
All zones normal during Exit Delay Period
System armed after Exit Delay expired
System is or was in alarm (alarm occurred)
System in alarm memory
System is forced to arm and the abnormal zone(s) is isolated

by the system
System in power-up delay or in Standby mode

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...