background image

L

N

POWER TRANSFORMER

CHASSIS

(CABINET)

315mA

FUSE

AC POWER

TERMINAL BLOCK

CABINET

AC INPUT

POWER CORD

RUBBER

RING

TO AN UNSWITCHED

MAINS RECEPTACLE

( 220 - 240VAC )

B) CONNECTION OF THE POWER CORD TO THE AC POWER TERMINAL

BLOCK (For "T" Version only)

!

!

!

!

!

!

The "T" Version alarm control panel comes with a built-in power transformer. Its

Secondary side (16.5VAC) was connected to Terminals 1 and 2 of the main circuit

board at the factory and that the Primary side is connected to an AC power terminal

block which is prepared for the AC input power cord connection.
Secure the AC input

power cord firmly to

the terminal block

according to the

indications below:

: LIVE
: EARTH (GROUND)
: NEUTRAL

Put the rubber ring (provided) on the feed through hole for the AC input power cord

to prevent from scratch.
The AC input power cord connecting to the Primary side of the power transformer

MUST be connected to an unswitched Mains receptacle for continuous AC power.
The power transformer is protected with a 315mA/250V fast blow glass fuse at the

primary side.
If fuse opens, remove AC and DC power, remove the short or overload condition, then

replace the fuse before restoring power. DO NOT substitute a higher rated fuse.

This terminal provides an unsw12V output power referring to the common ground.

It gives output power all the time no matter the system is armed or disarmed. Suitable for

those devices require uninterrupted power supply. Such as smoke detectors, control

keypads etc. This terminal is equipped with a 750mA resettable fuse.
Common Ground (-)
This terminal provides a cont12V output power at normal condition of no alarm

occurred. Mostly suitable for the connection of Satellite Siren/Strobe Light. The +12V output

is switched OFF at alarm condition. The output is equipped with a 2.5A resettable fuse.

A Satellite Siren-Strobe Light unit is a self-contained device with built-in backup battery

which is charged by the hold-off voltage from the control panel at normal condition. At

which, the siren and strobe light are OFF. At alarm condition, the hold-off voltage from the

control panel is cut. The siren and strobe light at the unit start to work. They are supplied by

the backup battery. The siren will stop when the pre-set time expires, and that the strobe

light will work until the hold-off voltage resumes.

A Satellite Siren-Strobe Light is self-protected and tamper-proof. It gives alarm instantly if

the connection wire between the unit and the alarm control panel is cut.
This terminal provides a cont12V output power at and after alarm condition until

the system is disarmed. It is mostly suitable for providing power for the stand alone strobe

light or those devices require continuous operation at alarm condition after the siren timer

is reset. The output is equipped with a 2.5A resettable fuse.

L

N

3:

4:
5:

6:

REMARK:

6

CONNECTION TERMINALS

HA-263

23

HA-263D (START THE PROGRAMMING)

REFRESH THE SYSTEM TO ITS DEFAULT VALUES

EXIT PROGRAMMING MODE

(Location 21)

LOCATION

ENTRY OF CODE

VALIDATION

2 1

0 0

#

Once the system is refreshed, all the programmed values in their Locations will be cleared or

setting back to their default values except the Master code in Location 01.

a) Location 11, User Code 1 --- Cleared
b) Location 12, User Code 2 --- Cleared
c) Location 13, User Code 3 --- Cleared
d) Location HOME-------------------- All Zones are Cleared
e) Location 14, The Beeps ------- 1 1 1 1 (All beeps enabled)
f) Location 15, Zone response Time --- 3 3 3 3 3 3 3 3 (All zones set on 500mS)

VALIDATION

Every time after programming is finished. It is necessary to set system to exit programming

mode and back to normal operation. It can be done at anytime by pressing the

key twice.

!

!

The Default Values after refresh

4

HA-263

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...