L
N
POWER TRANSFORMER
CHASSIS
(CABINET)
315mA
FUSE
AC POWER
TERMINAL BLOCK
CABINET
AC INPUT
POWER CORD
RUBBER
RING
TO AN UNSWITCHED
MAINS RECEPTACLE
( 220 - 240VAC )
B) CONNECTION OF THE POWER CORD TO THE AC POWER TERMINAL
BLOCK (For "T" Version only)
!
!
!
!
!
!
The "T" Version alarm control panel comes with a built-in power transformer. Its
Secondary side (16.5VAC) was connected to Terminals 1 and 2 of the main circuit
board at the factory and that the Primary side is connected to an AC power terminal
block which is prepared for the AC input power cord connection.
Secure the AC input
power cord firmly to
the terminal block
according to the
indications below:
: LIVE
: EARTH (GROUND)
: NEUTRAL
Put the rubber ring (provided) on the feed through hole for the AC input power cord
to prevent from scratch.
The AC input power cord connecting to the Primary side of the power transformer
MUST be connected to an unswitched Mains receptacle for continuous AC power.
The power transformer is protected with a 315mA/250V fast blow glass fuse at the
primary side.
If fuse opens, remove AC and DC power, remove the short or overload condition, then
replace the fuse before restoring power. DO NOT substitute a higher rated fuse.
This terminal provides an unsw12V output power referring to the common ground.
It gives output power all the time no matter the system is armed or disarmed. Suitable for
those devices require uninterrupted power supply. Such as smoke detectors, control
keypads etc. This terminal is equipped with a 750mA resettable fuse.
Common Ground (-)
This terminal provides a cont12V output power at normal condition of no alarm
occurred. Mostly suitable for the connection of Satellite Siren/Strobe Light. The +12V output
is switched OFF at alarm condition. The output is equipped with a 2.5A resettable fuse.
A Satellite Siren-Strobe Light unit is a self-contained device with built-in backup battery
which is charged by the hold-off voltage from the control panel at normal condition. At
which, the siren and strobe light are OFF. At alarm condition, the hold-off voltage from the
control panel is cut. The siren and strobe light at the unit start to work. They are supplied by
the backup battery. The siren will stop when the pre-set time expires, and that the strobe
light will work until the hold-off voltage resumes.
A Satellite Siren-Strobe Light is self-protected and tamper-proof. It gives alarm instantly if
the connection wire between the unit and the alarm control panel is cut.
This terminal provides a cont12V output power at and after alarm condition until
the system is disarmed. It is mostly suitable for providing power for the stand alone strobe
light or those devices require continuous operation at alarm condition after the siren timer
is reset. The output is equipped with a 2.5A resettable fuse.
L
N
3:
4:
5:
6:
REMARK:
6
CONNECTION TERMINALS
HA-263
23
HA-263D (START THE PROGRAMMING)
REFRESH THE SYSTEM TO ITS DEFAULT VALUES
EXIT PROGRAMMING MODE
(Location 21)
LOCATION
ENTRY OF CODE
VALIDATION
2 1
0 0
#
Once the system is refreshed, all the programmed values in their Locations will be cleared or
setting back to their default values except the Master code in Location 01.
a) Location 11, User Code 1 --- Cleared
b) Location 12, User Code 2 --- Cleared
c) Location 13, User Code 3 --- Cleared
d) Location HOME-------------------- All Zones are Cleared
e) Location 14, The Beeps ------- 1 1 1 1 (All beeps enabled)
f) Location 15, Zone response Time --- 3 3 3 3 3 3 3 3 (All zones set on 500mS)
VALIDATION
Every time after programming is finished. It is necessary to set system to exit programming
mode and back to normal operation. It can be done at anytime by pressing the
key twice.
!
!
The Default Values after refresh
4
HA-263