THE PROGRAMMING JUMPERS

The system allows the owner to set the desired functions directly with jumpers. The overall

programming is exceptionally easy and no learning is required.
There are 8 jumpers on the circuit board provide the following feature settings.

There are two positions available for System Setting with jumper.

--- Always put jumper on KS position for the system

using Key-Switch for arm-disarm control (HA-263K). Once the jumper is

on KS position, all the values programmed with the Digital Keypad will

be refreshed to the default values and all the protection zones are set to

have response time of 500mS that is the mostly suitable response time

for most of the sensors' alarm output.

--- Always put jumper on DK Position for the system

using Digital Keypad (HA-263D) for arm-disarm control. Once the jumper

is on DK position, the system allows to program the additional features

available for HA-263D from the keypad. Please see the features stated in

the HA-263D section.

Put jumper on DK Position also for the system operating in

combination of both Keyswitch and Digital Keypad for arm-disarm

control.

Entry Delay is the time setting for the delay zones 1, 4 and 7 for the people

to enter the protected area before activating the alarm outputs. There are 4

entry delay times available for selection. They are 15, 30, 60 or 90 seconds.

This is the time setting for the "+12V O/P AT ALARM (TIMING)" relay output.

The alarm output is auto-reset after time out. 4 positions are available for the

time settings. They are 3, 5, 15 minutes or no time out for the output relay.

Some cities have noise pollution control and do not allow alarm output with

no time out. Do not set alarm duration with no time out unless the alarm

output is not for driving siren or bell.

1) SYSTEM SETTING

2) ENTRY DELAY

3) ALARM DURATION

a) KS (Key Switch)

b) DK (Digital Keypad)

Remark:

REMARK:

10

SYSTEM

15

60 90

30

ENTRY DELAY

(SECONDS)

15

3

5

ALARM

DURATION

(MINUTES)

HA-263

FEATURE PROGRAMMING

PROGRAMMING PREPARATION

ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE -- 8080

In case the Master Code is forgotten. The owner requires to apply the following procedures to

make system in programming mode with the System Code 8080.

Switch OFF both AC and battery power for 1 minute to ensure the system is fully discharged.
Switch ON power again. The system will be in Standby mode for 1 minute. The AC power

and the Battery LED flash alternatively and short beeps will be heard. This is the only time

period that allows to key in the System Code 8080.

SYSTEM CODE

VALIDATION

8080

The keypad generates 2 beeps to confirm that system is in programming mode and the

"System Standby" finishes instantly after keying in the system code.
The PROGRAM LED is ON.
If the system code is not keyed-in within the Standby period, the system will go back to

normal operation and refuse any data entry for programming. To set it back to system

Standby mode, repeat procedures (1) and (2) are necessary.

The system refuses the entry of the System Code 8080 if the Standby mode is set up

with key-switch. Only the Standby mode after power-up is valid.

1)
2)

NOTE:

!
!

!

1)

2)
3)

4)

1)
2)

3)

Make sure the system is in disarmed mode and no alarm memory existing at the protection

zones in all partitions.
Set system in programming mode with Master Code.
System generates 2 beeps for successful code entry and 5 beeps for unsuccessful code

entry.
The system stops all its normal function while it is in programming mode.

Key in the Master Code and validate it with

.

For the owner's convenience in programming at the first time, factory has put a Master Code

1234 into the system. To compromise security, in all case, the owner should program a

personal Master Code to invalidate the factory set Master Code.
In the case that the factory Master Code 1234 was replaced by owner's Master Code, use the

owner's Master Code to set system in programming mode.

THE FACTORY OR OWNER'S MASTER CODE

VALIDATION

MASTER CODE

The keypad generates 2 beeps to confirm that system is in programming mode
The PROGRAM LED is ON

SET SYSTEM IN PROGRAMMING MODE

!

!

19

4

HA-263

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...

Reviews: