24
OPERATION
NOTE: FORCE TO ARM
ARM THE SYSTEM
ARM THE SYSTEM INSTANTLY (NO EXIT DELAY)
1)
2)
1)
2)
Make sure that the alarm system is in disarmed mode and no alarm memory is existing on
the zone indicator. If exists, clean it first.
Enter an appropriate User Code and validate with [#] key
USER CODE
#
2-beep confirms correct code entry, exit delay starts and EXIT/ARMED LED flashes.
5-beep indicates incorrect code entry. Enter your code again.
System will arm after exit delay expired. The appropriate partition LED and the EXIT/ARMED
LED are ON.
Make sure that the system is in disarmed mode and no alarm memory exists.
Enter an appropriate User Code, press the [ ] key, enter [2] and validate with [#] key.
USER CODE
2
#
2-beeps confirms correct code entry and the system arms instantly. The partition LED and
the EXIT/ARMED LED are ON.
As the system arms instantly, you may not be able to walk through the protected area. The
control keypad must be installed outside the protected area.
!
!
!
!
!
The User Code that stated in the description of operation stands for the code for arm-disarm
control of partition 1, partition 2 or the whole system.
User Code 1 for Partition 1
User Code 2 for Partition 2
User Code 3 for the Whole System
This system is designed with "Forced To Arm" operation. If faulty zones exist it will bypass the
faulty zones automatically after it is armed. The LED of the faulty zones will flash to indicate that
they are not protected and the "Forced To Arm" LED will also flash to warn the owner that the
system is Forced To Arm with the faulty zones bypassed.
a)
b)
c)
HA-263
CONNECTION TERMINALS
1, 2:
AC Power is supplied from a 16.5V AC, 1.5Amp minimum transformer at 50 or 60Hz. The
primary side of the transformer must be connected to an unswitched receptacle.
a) The transformer to be used in this product must be complied in the E N 6 1 5 5 8
standard
for European countries.
b) The system gives 1 minute Standby Delay instantly once it is powered-up
AP-980 power transformer is recommended for 220-240V AC operation, which is 16.5VAC
output, 3 Amp maximum rating. Power transformer is purchased separately.
Connect the 16.5VAC output voltage to terminals 1 and 2
on the board.
Wiring to the AC transformer must not exceed 100 feet
using 16 gange wire. The voltage reading between
terminals 1 and 2 of the control must not fall below
16.5VAC. Always put the power transformer closed to the
control.
Do not plug the transformer into AC outlet until all wiring
connections to the control are complete. As a safety
precaution, always power down the control when making
such connection.
The power transformer can be fixed on wall with screw.
NOTE:
(Model: AP-980)
A) CONNECTION OF POWER TRANSFORMER
!
!
!
!
5
WARNING:
!
!
THIS EQUIPMENT IS ONLY TO INSTALL BY QUALIFIED PERSONNEL
TAKE IT TO QUALIFIED SERVICEMAN WHEN SERVICE OR REPAIR WORK IS
NEEDED
PARTITION
1
PARTITION
2
COMMON
KEYPAD
HA-263D
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
2
3
4
5
6
7
8
2.2K
N.C.
N.O. N.O.
N.C.
2.2K
1K
1K
1K
DELA
Y
SYSTEM
ST
ATUS
PARTITION
2
ST
ATUS
PARTITION
2
ON-OFF
PARTITION
1
ON-OFF
+
12V
O/P
AT
ALARM
(TIMING)
+
12V
O/P
AT
ALARM
(LA
TCH)
+
12V
O/P
AT
NORMAL
+
12V
OUTPUT
(UNSWIT
CHED)
16.5V
AC
+
12V
KEYP
AD
D
AT
A
KEYP
AD
CL
OCK
COMMON
GND
(
)
-
COMMON
GND
(
)
-
PARTITION
1
ST
ATUS
DELA
Y
DELA
Y
INST
ANT
INST
ANT
INST
ANT
INST
ANT
24
HOUR
INST
ANT
~
AP-980
16.5VAC
4
HA-263