INTRODUCTION

HA-263 is a high performance local alarm control panel designed for home and office protections.

It features simple to use and simple to set up the system with minimum programmings. All the

main features can be set up via the jumpers on the circuit board. Absolutely no learning is

required. It is an ideal system for both "Do-it-yourself" and professional users.
The HA-263 comes with 3 partitions, they are partition 1, partition 2 and the common partition.

Partitions 1 and 2 are independently controlled for arm-disarm just like two alarm control panels,

which give the maximum flexibility for user's convenience and protection arrangement. The

common partition consists of one lobby protection zone and one 24 hour protection zone. The 24

hour zone works all the time for emergency alarms, such as fire, panic etc.. The lobby protection

zone is armed while both partitions 1 and 2 are armed to give maximum protection; and it is

disarmed while one of the partitions is disarmed. This allows either partition to arm, while leaving

the lobby for access into the other partition.
The HA-263 is offered with two versions, the HA-263K is arm-disarm controlled with keyswitch for

simple operation. The HA-263D comes with a digital keypad for arm-disarm control with user

codes, which also offers some additional features via programming on keypad.
The system can also be controlled with keyswitches and digital keypads in mixed operation. The

combined number of keyswitches and digital keypads are 4 maximum in total.
The features of the 8 protection zones in the 3 partitions are as follows:

Partition 1
ZONE 1 --- Delay
ZONE 2 --- Instant
ZONE 3 --- Instant
Partition 2
ZONE 4 --- Delay
ZONE 5 --- Instant
ZONE 6 --- Instant
Common Partition
ZONE 7 --- Delay (Lobby)
ZONE 8 --- 24 Hour Instant

!

!

!

HA-263

25

HA-263D (OPERATION)

ARM THE SYSTEM FOR HOME MODE (FOR USER CODE 3 ONLY)

ARM THE SYSTEM FOR HOME MODE INSTANTLY

ARM THE SYSTEM WITH MANUALLY BYPASSED ZONE(S)

1)
2)

3)

NOTE:

1)
2)

1)
2)
3)

4)

This function can only be done with User Code 3
The protection zones stored in memory will be bypassed when the system is armed for home

mode.
Enter User Code 3, press [HOME] and validate with [#] key.

USER CODE 3

HOME

#

2-beep confirms correct code entry, exit delay starts and EXIT/ARMED LED flashes.
The bypassed zone LEDs flash all the time to indicate that the zones are not protected
System will arm after exit delay expired. The appropriate partition LED and the EXIT/ARMED

LED are ON.

You are allowed to move about freely inside the premises that the protection zones are

bypassed.

The User Code 1 or User Code 2 still can be used to disarm its specific partition while

the system is operating on HOME mode.

The system arms instantly without Exit Delay on HOME mode.
Enter User Code 3, press [HOME], enter [2] and validate with [#] key.

USER CODE 3

HOME

2

#

2-beep confirms correct code entry and arms instantly for HOME mode.

In some circumstances, making bypass to the protection zone(s) temporary may be required,

such as:

To bypass the faulty zone(s).
To bypass the zone(s) that is not the habitually bypassed zone(s) in memory.
User Code 1 can only make bypass to the protection zones in partition 1 excluding the

common zones.
User Code 2 can only make bypass to the protection zones in partition 2 excluding the

common zones.

!

!

!

!

!

.

(FOR USER CODE 3 ONLY)

4

HA-263

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...

Reviews: