background image





3) Example 3 -- EM Card + Secondary User 

Code

 :

i)  Programming :

       (a)       (b)         (c)                (d)                    (e)              (f)
(a) The card is programmed for operating Output 1
(b) The operation medium is EM Card + Secondary User Code
(c) Take the ID number 002 in Group 1 to store the Card & Code, which is one of the IDs in 000-999
(d) Put the card close to the reader. One beep confirms the reading
(e) Put Secondary User Code “2 4 6 8 0” after reading of card
(f) Press # to store the “Card + Secondary User Code”, two-beep confirms a valid entry

ii) Operation : (while the system is back to operation mode)

     

           (a)                       (b)                 (c)
(a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for 

entry of the User Code, the Amber LED keeps flashing

(b) Key in the Secondary User Code “2 4 6 8 0”
(c) Confirm it with the # key. Output 1 activates

Read Card

Read Card

4) Example 4 -- EM Card + Common User Code:

i) Programming :

         (a)      (b)         (c)                (d)           (e)
(a) The card is programmed for operating Output 1
(b) The operation medium is “EM Card + Common User Code”
(c) Take ID number 003 in Group 1 to store the card, which is one of the IDs in 000-999
(d)       

(e) Press # to store the “Card”. Two-beep confirms a valid entry

ii) Operation : (while the system is back to operation mode) 

           

           (a)                              (b)                    (c)
(a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for entry 

of the Common User Code, the Amber LED keeps flashing

(b) Key in the Common User Code “1 3 5 7” (the number programmed in “Location 0 3” for Output 

1 in the previous Example)

(c) Confirm it with the # key. Output 1 activates

Read Card

Common User Code

Read Card

Read the EM card. One beep confirms the reading. (No need to key in a Common User Code but 

there MUST be a Common User Code already recorded in Location 03; (or 04 for O/P 2).

INTELLIGENT EGRESS BUTTON – AN UNIQUE FEATURE OF THE KEYPAD

 

INTRODUCTION

Most of the keypads for access control are just for controlling “Going In” from outside. It is not 

enough for today’s access control systems. In fact, controlling “Going Out” is also very important in 

some public passage areas those are not allowed to use locks or digital keypads for stopping of 

“Going Out” due to safety reasons. Such as hospitals, kindergartens, elderly homes, convenient 

stores, emergency exits etc.. The wardens, teachers, shopkeepers and the guards are always 

required to keep an eye on people to prevent unattended leaving, shoplifting, and unauthorized use 

of the emergency exits.

The Intelligent Egress Button can be programmed to do something to get attention from the person 

on duty before the door is opened. The button offers programmable egress delay, delay with 

warning, holding button for the delay, momentary button contact with warning for the delay and 

even gives alarm when a controlled door is opened.

Locations 90 is the place for setting the desired functions for the Egress Button.

The functions programmed to the Egress Button do not affect the normal operation of the keypad. 

The operation of the keypad with Code or Card is always in the first priority to give instant action to 

the output relay 1 for door strike.

It is 

NOT

 required to program the Egress Button with the special function in normal use. Just leave 

it on its default values.

WHERE AND WHY “GOING OUT” NEEDS ATTENTION

Examples for some areas may need an Intelligent Egress Button:

Hospital:

Some of the patients are not allowed to leave the ward without doctor’s permission. An egress 

button with exit delay and warning beeps will help the nurse or warden to get attention to the door 

when the egress button is pressed. Further setting of the egress button with holding contact delay 

even gives higher level of security to a controlled door.

Kindergarten:

Young children are always active. Some of them may be willing to go out to explore their ways of 

playing. For safety reason, teachers have to watch all of them in the attended area. Leaving school 

alone without the companion of parents or teacher is dangerous to young children. An egress button 

with delay and warning beeps will be helpful to prevent the children trying to go out without getting 

the attention of the teacher.

Elderly Home:

The elderly needs constant attention and care. Some old people have poor memory. They may forget 
the way to come back if they leave home alone. An egress button with delay and warning beep will 

easily get the attention of the warden before the door is open.

Convenient Store:

Most of the convenient stores have just only one or two shopkeepers on duty. They are usually the 

cashier. Shoplifting may easily happen while the shopkeeper is busily serving customers at the 

cashier desk. A holding contact egress button with delay and warning beeps may help to stop most 

of the shoplifting. As the thief knows that he is gotten attention by the shopkeeper before the door 

is open.

Summary of Contents for DK-2852C

Page 1: ...VANDAL RESISTANT BACK LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD DK 2852 C D User Manual FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...ct means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed...

Page 4: ...ation Control Output Relay 2 1A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads for sys...

Page 5: ...hes to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only...

Page 6: ...ILIARY TERMINALS C KEY ACTIVE a b The Key Active Output switches to ground for 10 seconds whenever a key is touched You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or to...

Page 7: ...the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel with the Data I O Bus They provide the...

Page 8: ...ECTION TERMINALS 3 Split decoded Access Control Door Lock Description Apart from stand alone operation the DK 2852 can be up graded to high security Split decoded operation with a decoder unit DA 2800...

Page 9: ...Warning The keypad generates door forced open warning instantly once the door is forced to open without a valid user Code Card or egress button The warning lasts as long as the time programmed 1 999 s...

Page 10: ...door position sensing switches for the two doors 16 17 TAMPER N C Tamper Switch Normally Closed Contact A normally closed dry contact while the keypad is secured on its box It is open while keypad is...

Page 11: ...eep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Activation 1 Second Long...

Page 12: ...User Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the sta...

Page 13: ...with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code instead of Secondary user...

Page 14: ...r power has been applied It is the time frame designed for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minu...

Page 15: ...ogramming Code The system back to normal opration after programming Pacifier Tone ON OFF 7 1 FUNCTION MODE 0 NO Notification 2 2 Short Beeps 1 1 Second Long Beep FUNCTION MODE 0 OFF 1 ON FUNCTION MODE...

Page 16: ...ting system program It can not be changed in any ways PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2 Su...

Page 17: ...sed with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locatio...

Page 18: ...be used to reset an operating output timer instantly Output 1 Activates or Resets Output 2 Activates or Resets Optional Functions Controlled by Super User Code for Output 1 Apart from controlling of t...

Page 19: ...LIDATION Press key once Two beep confirms the entry or 3 2 1 CLOSE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming The button is equivalent...

Page 20: ...eps confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay tim...

Page 21: ...card once and confirm It does not require the ID number The Card includes the combinations of 1 Card Only 2 Card Secondary User Code and 3 Card Common User Code 1 2 5 4 3 Location Clearing takes few s...

Page 22: ...o operation mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...o prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before the...

Page 24: ...e Whole Group of Users Whole group of users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Gr...

Page 25: ...on 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for th...

Page 26: ...User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic acc...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work overt...

Page 29: ...t in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until the...

Page 30: ...our real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required if d...

Page 31: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter...

Reviews: