background image

PREPARATION FOR PROGRAMMING

A) CRITERIA FOR CODES AND CARDS

1) Prime Codes

The prime codes include the a) User Codes, b) Master Code, c) Duress Codes, d) Super User Codes, 

e) Common User Codes and f) Visitor Codes. All these codes 

MUST

 be unique. It is not allowed to 

repeat a prime code for second function.

All the codes in this system can be 4-8 digits for Manual Entry Mode. The codes must be in the same 

digit length with the Master Codes for Auto Entry Mode. See Location 70 for the details.

2) Prime Cards

All the User Cards are prime cards. They are not allowed to program for second function. e.g. a card 

was programmed for operating output 1 is not allowed for output 2.

The cards used in this system are 125Khz proximity EM cards.

3) Secondary User Codes

A Secondary User Code is prepared to enhance the security of an user card, which is a code put after 

a card. The keypad requires both card and code are correct to grant an entry. The secondary code 

can be repeatedly used for a group of cards; or proprietary with one code for one card.

NOTE:

The keypad will reject repeated use of prime card or prime code in programming and give one long 

beep indication.

B) SECURITY LEVEL OF THE OPERATION MEDIA

The keypad provides 5 operation Media for owner’s selection of security level. See programming 

Location 10, 20 & 30

1) EM Card Only – Operation Media 1

A general way for access control, just simply read a card to open the door. Security level is moderate 

but it is user convenient.

2) User Code Only – Operation Media 2

A general way for access control, just simply enter a code to open the door. Security level is 

moderate but it is user convenient.

3) EM Card + Common User Code – Operation Media 4

The keypad requires both Card and Common User Code are correct to grant an entry. Common User 

Code is an user code for all the cards. Two media are used in door control. The security level is better 

than just card or user code alone.

This operation mode can also report Duress Alarm by keying the duress code instead of common 

user code in emergency when the user is forced to open the door.

4) EM Card + Group Secondary User Code – Operation Media 3

A secondary user code can be repeatedly used for a group of cards in a department. Owner can 

make a proprietary department code for each department in a company. Only the staff of the 

department holding a card and knowing the code is accepted to enter. This approach increases the 

departmental security and prevents a lost card picked up by other group of people in the company 

to open the door.

This operation mode can also report Duress Alarm by keying the duress code instead of common 

user code in emergency when the user is forced to open the door.





APPLICATION EXPANSIONS

Apart from standard-alone operation, DK-2852 is expandable to be a Multi-station System or a High 

Security Multi-station Split-decoded System with its Data I/O Bus for the connection of the optional 

auxiliary keypad(s) and decoder. The wiring is very simple. Just connect all the related devices in 

parallel with the Data I/O Bus. The DK-2852 is the server that manages the data among them.

A Multi-station System provides higher security in access control and user convenience to operate an 

electric lock at different locations. Such as a dual keypad system for area needs controlling of going 

in and going out with user codes or EM cards.

A Split-decoded keypad system increases the overall security with keypad(s) installing outside and 

decoder installing inside. It prevents the door can be opened due to sabotage at the external 

keypad(s). A Split-decoded system is also compatible with the auxiliary keypads for multi-station 

operation. It is a perfect system for overall higher security and user convenience.

The application examples here show the connections of the auxiliary keypads and the decoder to the 

server keypad. Please contact your local agent for these optional devices if increasing security and 

user convenience to the system is required.

The auxiliary reader / keypads and the decoders are compatible with all the keypads in the DK-2800  

MK-II series.

The version"A" auxiliary reader keypads are available, which provide Wiegand and RS-232 data 

outputs.

Connection Terminal

AR-2809

AR-2806

AR-2802 and AR-2807

Aux. Reader-Keypad

Aux. Reader-Keypad

Aux. Reader-Keypad

Aux. Reader

AR-2809

AR-2807

AR-2806

AR-2802

The Axiliary Readers & Keypad (Optional)

Version"A" 

 ONL

Y

Version"A" ONLY

Summary of Contents for DK-2852C

Page 1: ...VANDAL RESISTANT BACK LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD DK 2852 C D User Manual FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...ct means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed...

Page 4: ...ation Control Output Relay 2 1A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads for sys...

Page 5: ...hes to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only...

Page 6: ...ILIARY TERMINALS C KEY ACTIVE a b The Key Active Output switches to ground for 10 seconds whenever a key is touched You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or to...

Page 7: ...the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel with the Data I O Bus They provide the...

Page 8: ...ECTION TERMINALS 3 Split decoded Access Control Door Lock Description Apart from stand alone operation the DK 2852 can be up graded to high security Split decoded operation with a decoder unit DA 2800...

Page 9: ...Warning The keypad generates door forced open warning instantly once the door is forced to open without a valid user Code Card or egress button The warning lasts as long as the time programmed 1 999 s...

Page 10: ...door position sensing switches for the two doors 16 17 TAMPER N C Tamper Switch Normally Closed Contact A normally closed dry contact while the keypad is secured on its box It is open while keypad is...

Page 11: ...eep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Activation 1 Second Long...

Page 12: ...User Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the sta...

Page 13: ...with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code instead of Secondary user...

Page 14: ...r power has been applied It is the time frame designed for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minu...

Page 15: ...ogramming Code The system back to normal opration after programming Pacifier Tone ON OFF 7 1 FUNCTION MODE 0 NO Notification 2 2 Short Beeps 1 1 Second Long Beep FUNCTION MODE 0 OFF 1 ON FUNCTION MODE...

Page 16: ...ting system program It can not be changed in any ways PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2 Su...

Page 17: ...sed with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locatio...

Page 18: ...be used to reset an operating output timer instantly Output 1 Activates or Resets Output 2 Activates or Resets Optional Functions Controlled by Super User Code for Output 1 Apart from controlling of t...

Page 19: ...LIDATION Press key once Two beep confirms the entry or 3 2 1 CLOSE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming The button is equivalent...

Page 20: ...eps confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay tim...

Page 21: ...card once and confirm It does not require the ID number The Card includes the combinations of 1 Card Only 2 Card Secondary User Code and 3 Card Common User Code 1 2 5 4 3 Location Clearing takes few s...

Page 22: ...o operation mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...o prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before the...

Page 24: ...e Whole Group of Users Whole group of users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Gr...

Page 25: ...on 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for th...

Page 26: ...User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic acc...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work overt...

Page 29: ...t in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until the...

Page 30: ...our real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required if d...

Page 31: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter...

Reviews: