5) To program a new Master Code to replace the old one. See “

Record A Master Code

 

stated at 

“Location 01” for the details.

NOTE:

The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is 

not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat 

procedures 1-4.

SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9                        

       

The keypad can be refreshed by cleaning all the programmed old data and set it back to default 

values except the

 Master Code

.

      
                       

     

REFRESHING CODE                          VALIDATION

   

NOTE:

a) 
b) 
c)

 



Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are 

necessary.



SYSTEM  

CODES

FUNCTION

CODE ENTRY

RESULTS

0 0 0 0

system in programming Mode at the first

Factory Set Master Code for User to set 

time.

THIS IS NOT A PERMANENT SYSTEM 

CODE & IT IS CHANGED IF A NEW 

MASTER CODE IS PROGRAMMED.

  

OR

 NEW MASTER CODE  

  

System in 

Programming Mode

9 9 9 9

REFRESH CODE

 -- Refresh the system 

and set all its function back to default 

values.

 

All programmed 

data are cleared 

and back to the 

default values 

except the Master 

Code

2 8 2 8

DAP CODE

-- Direct access to 

programming mode. Valid only in the 

power-up delay period

 

System in 

Programming Mode

0 9 9 9

USER Codes / Cards whole group 

clearing Code for the selected Location

LOCATIONS

:

10--- User Group 1
20--- User Group 2
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2

 LOCATION NO.  

  

Whole group 

of users in the 

selected location 

are cleared

* *

Exit Programming Code



The system back 

to normal opration 

after programming

Pacifier Tone ON-OFF

7 1

FUNCTION MODE:

0---NO Notification

2---2 Short Beeps

1---1 Second Long Beep

FUNCTION MODE:

0---OFF

1---ON

FUNCTION MODE:

0---OFF

1---ON

 

FUNCTION MODE

 

Mode = 1, 

ON

7 2

Output Announcer

 

FUNCTION MODE

 

7 3

Standby LED Flashing

 

FUNCTION MODE

 

Mode = 1, 

Flashing ON

Mode = 1

 

1 Second 

Long Beep

Pacifier Tone  

8 0

Door Forced Open 

Warning & Time

FUNCTION MODE / TIME:

0---OFF

1-999 Seconds

 

FUNCTION / TIME

 

Mode = 0, 

Door Forced 

Open

Warning OFF

8 1

Propped-up Warning & 

Time

 

FUNCTION / TIME

 

Mode = 0, 

Propped-up 

Warning OFF

9 0

Egress Delay Warning 

CODE 1 

FUNCTION 

MODE:

1---Momentary, No warning
2---Momentary, with 

warning
4---Hold Contact, No 

warning
5---Hold Contact, with 

warning

CODE 2 

DELAY TIME:

 

0---No Delay

1-99 Seconds

 

CODE 1

 

CODE 2

 

Mode = 1 

Momentary, 

No warning

TIME = 0

No Delay

9 4

Operation Mode 

FUNCTION MODE: 

 

MODE

 

Mode = 0 

Keypad 

Mode

1---Server Mode

0---Keypad Mode

DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8             

               

In case the Master Code is forgotten, apply the following procedures precisely to set keypad 
into programming mode with DAP code:

1) 

2) 

 

3) 

4) 

Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.

Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives 

continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP 

code.

Press the Egress Button (the button connecting accross EG IN, (Terminal 9) and (-)GND, 

(Terminal 15) once to enable the keypad for accepting DAP code. The power-up beep stops after 

the Egress Button is pressed.

Key in the DAP code                    and validate it with             (or             ). The Status LED is 
ON and the keypad is in programming mode like using Master Code. It is ready to accept new 
programming data as long as you like until exit programming mode.

PRESS ONCE

EGRESS BUTTON                      DAP CODE                        VALIDATION

Summary of Contents for DK-2852C

Page 1: ...VANDAL RESISTANT BACK LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD DK 2852 C D User Manual FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...ct means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed...

Page 4: ...ation Control Output Relay 2 1A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads for sys...

Page 5: ...hes to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only...

Page 6: ...ILIARY TERMINALS C KEY ACTIVE a b The Key Active Output switches to ground for 10 seconds whenever a key is touched You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or to...

Page 7: ...the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel with the Data I O Bus They provide the...

Page 8: ...ECTION TERMINALS 3 Split decoded Access Control Door Lock Description Apart from stand alone operation the DK 2852 can be up graded to high security Split decoded operation with a decoder unit DA 2800...

Page 9: ...Warning The keypad generates door forced open warning instantly once the door is forced to open without a valid user Code Card or egress button The warning lasts as long as the time programmed 1 999 s...

Page 10: ...door position sensing switches for the two doors 16 17 TAMPER N C Tamper Switch Normally Closed Contact A normally closed dry contact while the keypad is secured on its box It is open while keypad is...

Page 11: ...eep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Activation 1 Second Long...

Page 12: ...User Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the sta...

Page 13: ...with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code instead of Secondary user...

Page 14: ...r power has been applied It is the time frame designed for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minu...

Page 15: ...ogramming Code The system back to normal opration after programming Pacifier Tone ON OFF 7 1 FUNCTION MODE 0 NO Notification 2 2 Short Beeps 1 1 Second Long Beep FUNCTION MODE 0 OFF 1 ON FUNCTION MODE...

Page 16: ...ting system program It can not be changed in any ways PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2 Su...

Page 17: ...sed with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locatio...

Page 18: ...be used to reset an operating output timer instantly Output 1 Activates or Resets Output 2 Activates or Resets Optional Functions Controlled by Super User Code for Output 1 Apart from controlling of t...

Page 19: ...LIDATION Press key once Two beep confirms the entry or 3 2 1 CLOSE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming The button is equivalent...

Page 20: ...eps confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay tim...

Page 21: ...card once and confirm It does not require the ID number The Card includes the combinations of 1 Card Only 2 Card Secondary User Code and 3 Card Common User Code 1 2 5 4 3 Location Clearing takes few s...

Page 22: ...o operation mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...o prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before the...

Page 24: ...e Whole Group of Users Whole group of users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Gr...

Page 25: ...on 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for th...

Page 26: ...User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic acc...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work overt...

Page 29: ...t in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until the...

Page 30: ...our real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required if d...

Page 31: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter...

Reviews: