--------------------------------------------------------------------------------6/50--------------------------------------------------------------------------------
It is recommended to protect the housing against heavy mechanical interactions and drippy fluids.
Attention!
The side of the housing showing the antenna symbol must not be brought next to a metal surface. This
could lead to a significant change of the properties of the antenna circuit, which in turn reduces the
reading range considerably
.
With the help of the plastic bars, the reader can mounted or screwed on to the most fastening elements
without open the housing of the device.
3.2
Grounding of the reader
To get reliable reading results, the reader must be grounded. The connector is placed at the side of the
housing (6.35 mm flat contact).
To avoid EMV-problems, the cable to ground ought to be very short with low impedance.
Attention!
The topology of the ground wires must be done in the right way (according state of art).
3.2.1
Connecting of the plug
Attention!
Be sure that the grounding of the reader is well done and the power supply is not connected(chapter 3.2).
Otherwise the electronic
may be
destroyed by electrostatic discharge (ESD).