--------------------------------------------------------------------------------24/50--------------------------------------------------------------------------------
PARAMETER
FUNCTION
0
No suppression
1
Suppression of equal transponder numbers
5.3.4
INIT – initialization
With the command INIT all paramters of this command set are set to the default values. After that
you can save the settings with the command VSAVE.
Input format:
INIT
<CR>
Output (example):
ACK
<CR>
5.3.5
MC – mirror code
With this command you can change the output order of the bytes from a transpondercode.
Input format:
MC
<CR>
Output (example):
0
<CR>
5.3.6
TOR – maximum reading time
Timeout time for the reader. TOR is used in operation mode 2 as maximum gating time for a reading
process. The length of the maximum gating time results from the equation gating_time = TOR * TB.
The time constant TB (time base) has always the default value 100ms.
Input format:
TOR
<SP>
parameter
<CR>
Output (example):
05
<CR>
Parameter:
PARAMETER
FUNCTION
00h
limits the reading process duration of exactly one reading cycle
01h..FFh
limits the reading process duration to maximum 1..256 times
TB