anticollision level 2
select 2
ISO 15693:
inventory
The reader answers the UID of a transponder. The length of the UID can be between 4 and 8 bytes.
Input format:
GT
<CR>
Output (example):
625E562A
<CR>
5.4.3
HD – halt detected code
The command HD mutes the last selected transponder.
Input format:
HD
<CR>
Output (example):
ACK
<CR>
5.4.4
MD – mode of operation
There a two modes of operation available. It is possible, that the reader reads constantly or triggered by
an instruction.
Input format:
MD
<SP>
parameter
<CR>
Output (example):
2
<CR>
Parameter:
PARAMETER
FUNCTION
0
constant reading mode
2
single reading mode
5.4.5
RD – read page
With the command RD you can read out a page of the transponder. The command executes internally the
commands get tag, if using mifare 1K/4K log in (with the key attuned to KM) and the reading command.
Input format mifare 1K/4K:
RD
<SP>
parameter 1
<SP>
parameter 2
<CR>
Input format ultralight:
RD
<SP>
parameter 2
<CR>