--------------------------------------------------------------------------------25/50--------------------------------------------------------------------------------
5.3.7
SI – set iso standard
With this command you can switch the iso standard of the reader.
Input format:
SI
<SP>
parameter
<CR>
Output (example):
0
<CR>
Parameter:
PARAMETER
FUNCTION
0
ISO 14443A
1
ISO 15693
5.3.8
VSAVE – variables save
With the command VSAVE the following parameters are saved to the internal EEPROM:
AFI
2
, KM
1
, KT
1
, MD, SI, TOR
Input format:
VSAVE
<CR>
Output (example):
ACK
<CR>
1
just available in the ISO 14443A standard
2
just available in the ISO 15693 standard
5.3.9
VS – variables show
With the command VS the reader shows the settings of the following parameters:
AFI
2
, KM
1
, KT
1
, MD, SI, TOR
Input format:
VS
<CR>
Output (example):
ACT
<SP>
14
<CR>
AM
<SP>
0
<SP>
…