18
EKI-9628G User Manual
2.9.5
Wiring the Power Inputs
There are two power inputs for normal and redundant power configurations. The
power input 2 is used for wiring a redundant power configuration. See the following
for terminal block connector views.
Figure 2.15 Terminal Receptor: Power Input Contacts
To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before
proceeding.
1.
Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and
loosen the screws.
2.
Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting
up power redundancy, connect PW2 in the same manner.
3.
Tighten the wire-clamp screws to secure the DC wires in place.
Figure 2.16 Installing DC Wires in a Terminal Block
Caution!
Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the switch device.The temperature rating of the Input Connection
Cable must be higher than 90
°
C.
Warning!
Power down and disconnect the power cord before servicing or wiring
the switch.
V1-
V1+
V2-
V2+
PWR1
PWR2
PWR1
PWR2
PWR1
PWR2
Loosening
Wire-clamp
Screws
Installing DC
Wires
Securing
Wire-
clamp Screws
Summary of Contents for EKI-9628G
Page 1: ...User Manual EKI 9628G 24G 4G Combo port L3 Managed Switch...
Page 14: ...Chapter 1 1Product Overview...
Page 19: ...Chapter 2 2Switch Installation...
Page 33: ...Chapter 3 3Configuration Utility...
Page 39: ...Chapter 4 4Managing Switch...
Page 144: ...EKI 9628G User Manual 131...
Page 145: ...132 EKI 9628G User Manual...
Page 146: ...Chapter 5 5Troubleshooting...