5.7.2
U
SING THE
S
ERIAL
I
NTERFACE
:
1.
Verify that the unit is in REMOTE control mode (REMOTE/LOCAL LED indicator is ON).
If not, switch to REMOTE mode as instructed in
Section 5.4
page 37.
2.
From Screen (menu) #1, use the ‘F9’ function key to select the SSPA and then ‘F7’
(‘MUTEoff ’).
5.8
STATUS DISPLAY SCREENS
The front panel display allows an operator to view information on a number of critical operating
parameters. Use
[
]
and
[
]
keys to move between the various displays and sub-menus.
The following are typical status displays.
5.9
AMPLIFIER SHUTDOWN
Amplifier shuts down due to an alarm or as a result of a hardware or software command.
A software shutdown is performed at either the front panel or by selecting the MUTE ON
function key sending the appropriate code via the RS-485 serial interface, see
Section 4.3.2
page 29. The amplifier can be restarted in a similar manner provided a hardware shutdown is not
in effect. The amplifier can also be restarted by switching power off & on the PA. Note that in a
redundant system, if the MUTE command is issued by the operator to the ON-LINE unit, the
system will automatically switch the other unit as ON-LINE and the muted unit as STANDBY.
When the amplifier resumes operation, the attenuation level will return to its previous setting
after about 2 minutes of stable operation. Note however that the amplifier will not restart if a
FAULT condition is detected.
STATUS: ____
REFL. PWR <nn.n dBm
STATUS: ____
OUTPUT PWR nn.n dBm
STATUS: ____
PA SHROUD nn.n °C
STATUS: ____
PA HOTSPOT nn.n °C
STATUS: ____
SUPPL CURR nn.n A
Summary of Contents for ARMA-C250-CRM
Page 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Page 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Page 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Page 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Page 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...