ARMA-C250-CRM
28
4.3
REMOTE INTERFACE
4.3.1
S
OFTWARE
I
NSTALLATION AND
S
ET
-
UP
The communications protocol for the serial interface is RS-485. To use the standard IBM
compatible personal computer (running DOS 3.1 or higher) with an RS-232 serial port, you must
use the RS-485/RS-232 adapter, to be provided as an option. In fact the software can be used to
control up to 16 different SSPAs from a single computer.
The following table provides wiring instructions for proper operation of the user interface.
TABLE 13
: SERIAL RS-485 INTERFACE CONNECTION INFORMATION
Serial Interface (J2),
Pin #
Active condition
RS-485/RS-232
Adapter, Pin #
6
Serial Transmit port, RS-485 TX + levels.
17
4
Serial Transmit port, RS-485 TX - levels.
3
9
Serial Receive port, RS-485 RX + levels.
14
3
Serial Receive port, RS-485 RX - levels.
2
5
System common.
1
1
Shield
CAUTION:
Direct connection or direct communication from (J2) of SSPA to RS-232 port
of PC will cause permanent damage to the controller of SSPA.
Summary of Contents for ARMA-C250-CRM
Page 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Page 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Page 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Page 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Page 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...