ARMA-C250-CRM
25
4.
OPERATION
4.1
INTRODUCTION
The amplifier may be operated via the RS-485 serial interface, discrete interface or the front
panel controls and display. Each method provides full access to the unit’s functions including
system monitoring of all key operating parameters, control of output attenuation and amplifier’s
operational status.
In LOCAL mode, with the aid of the keypad and the LCD display, the operator can navigate
through a series of menus on the front panel which allow the setting of key parameters and digital
display of critical performance indicators. A series of LED indicators provides a summary of the
operational status of the amplifier, see
at page 22
&
at page 22. In
REMOTE mode, using the software supplied with this product or a similar communications
software, the same monitor and control functions can be accessed via the RS-485 interface, see
Section 5.4
at page 37 for more information.
4.2
FRONT PANEL CONTROLS
Per
six keys on the front panel provide access to the various display
functions and allow local control of the amplifier. The display functions via a menu system which
provides quick access to all available monitor and control features.
Generally, the
[
]
and
[
]
keys are the primary means by which the operator moves between
different displays and menu options. The
[Enter]
key is used to select a menu item and to confirm
changes made to operating parameters. The
[Clear]
key is used to reset the FAULT status on an
amplifier once the condition that caused the fault has been corrected. For specific instructions on
the functionality of each sub-menu refer to the appropriate section of this manual.
Summary of Contents for ARMA-C250-CRM
Page 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Page 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Page 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Page 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Page 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...