ARMA-C250-CRM
36
5.
CONFIGURATION AND SET-UP
5.1
SOFTWARE CONFIGURATION
Insert the adapter in the desired serial port of the computer and connect the cable leading to the
amplifier to the adapter.
1.
The program ADV.EXE is located on the diskette enclosed with this amplifier. To use the
software, first copy ADV.EXE to your hard disk.
2.
To execute the program, at the DOS prompt type ADV.
3.
Connect your serial interface cable to the SSPA.
4.
At the prompt, enter the COMM (serial) port number you are using (1, 2, 3 or 4).
NOTE: The protocol is 9600 baud, 7 bits and even parity, see
5.
Press the function key ‘F10’ twice to obtain Screen (menu) #3.
6.
Select the ‘F7’ function key (COMSET) to configure the communications address for the
amplifier. This is the number that will be used to identify the specific SSPA for monitor and
control purposes.
7.
At the prompt, enter a value from 0 through 15. Restart the SSPA, the default value is 0.
From this point on, to access a specific SSPA for monitor or control purposes, use the function
key ‘F9’ on Screen (menu) #1. You will be prompted to enter the communication address of the
specific amplifier to be accessed.
Type ALT-X to exit the program.
5.2
RF CONFIGURATION
5.2.1
S
AFETY
C
ONSIDERATIONS
The VSWR protection at the output of the amplifier is designed to protect the unit against
accidental operation with no load at the RF output connector by causing the SSPA to shutdown
automatically.
Please note that failure of the amplifier due to above condition will be attributed to abuse or
neglect and is not covered by our standard warranty.
WARNING:
Prolonged operation without a load at the output may cause severe bodily
harm, loss of sight, even death. Do not operate amplifier if the output RF connector is not
connected to a load
.
Summary of Contents for ARMA-C250-CRM
Page 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Page 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Page 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Page 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Page 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...