ARMA-C250-CRM
16
2.5
SPECIFICATIONS
The SSPA specified herein is capable of meeting or exceeding the performance specifications
listed in the following table over frequency range, operating temperature and line voltage
variation unless otherwise specified. The SSPA will meet all RF performance specifications
within thirty minutes of application of prime power.
TABLE 1
: ELECTRICAL SPECIFICATIONS (EACH UNIT)
Frequency Range
5.850 - 6.450 GHz
Power Output (P1dB)
+ 53 dBm, min
Gain @ rated power
62 dB, min
Gain Flatness
2.0 dB p-p, max over 600 MHz (at room temperature)
0.6 dB, max over 40 MHz
Gain Variation
± 1.50 dB, max (0°C to +50°C)
Gain Stability over 24 hours
± 0.25 dB, max @ 25°C ambient
Variable output attenuation
18 dB, min
Accuracy of attenuation setting
± 1.0 dB, over frequency and temperature range
Input Return Loss (Power on)
18 dB, max
Output Return Loss (Power off)
20 dB, max
Noise Figure @ maximum gain
8 dB, max
Spurious at rated power
- 65 dBc, max
Harmonics at rated power
- 90 dBc, max
AM/PM Conversion at rated power
2.5 °/dB, typ.
Third Order Intermodulation
(Two equal tones 5 MHz apart)
- 36 dBc max. @ 7 dB back-off total power
- 26 dBc max. @ 3 dB back-off total power
Group Delay Linear
Parabolic
Ripple
0.02 ns / MHz, max.
0.003 ns / MHz
2
, max.
1 ns p-p typical
Residual AM
(F* = Frequency in kHz)
- 45 dBc
- 20 (1+ log F* ) dBc
- 80 dBc
(0 - 10 kHz)
(10 kHz - 500 kHz)
(500 kHz - 1 MHz)
Phase Noise
Meets IESS-308/309
Summary of Contents for ARMA-C250-CRM
Page 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Page 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Page 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Page 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...