Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 42 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
12.7 TEST RESULT
Date of Test
May 23, 2005
Temperature
23
℃
Test Mode
Mode 1
Humidity
65 %
Item
Phase
Angle
Reduction (%)
Test Duration
(ms)
Required
Criteria
Complied
to Criteria
Result
0
C
C
PASS
45
C
*
*
90
C
*
*
135
C
*
*
180
C
C
PASS
225
C
*
*
270
C
*
*
Voltage
Short
Interruptions
315
>95 5000
C * *
0
B
A
PASS
45
B
*
*
90
B
*
*
135
B
*
*
180
B
A
PASS
225
B
*
*
270
B
*
*
315
>95 10
B * *
0
C
A
PASS
45
C
*
*
90
C
*
*
135
C
*
*
180
C
A
PASS
225
C
*
*
270
C
*
*
Voltage
Dips
315
30 500
C * *
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss of function, provided the function is self-recoverable, or can be restored
by the operation of the controls
Additional
Information
There was no observable degradation in performance.
EUT stopped operation and could / could not be reset by operator at KV of
Line .
No false alarms or other malfunctions were observed during or after the test. The
acceptance criteria were met, and the EUT passed the test.