GESTEK
Lab
Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 19 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
5.8 RADIATED EMISSIONS MEASUREMENT RESULTS
Date of Test
May 21, 2005
Temperature
20 deg/C
EUT
Mother Board
Humidity
62 %RH
Working Cond.
Mode 1
Display Pattern
H Pattern
Antenna distance
10m at
Horizontal
Frequency Range
30-1000MHz
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB/m
Measurement
dBµV/m
Limit
dBµV/m
Over Limit
dB
Detector
1
125.0000 39.80 -13.98 25.82
30 -4.18 QP
2
165.9130 38.20 -15.44 22.76
30 -7.24 QP
3
172.8500 38.50 -15.75 22.75
30 -7.25 QP
4
192.0130 38.43 -15.65 22.78
30 -7.22 QP
5
200.0013 36.55 -15.87 20.68
30 -9.32 QP
6
233.4400 39.30 -13.17 26.13
37 -10.87 QP
7
★
240.0213
46.50 -12.77 33.73
37 -3.27 QP
8
299.9950 36.80 -10.22 26.58
37 -10.42 QP
9
400.0025 35.67 -7.78 27.89
37 -9.11 QP
10
480.0363 35.00 -6.29 28.71
37 -8.29 QP
11
500.0015 35.00 -6.16 28.84
37 -8.16 QP
12
540.0400 34.82 -5.44 29.38
37 -7.62 QP
13
600.0475 34.56 -4.05 30.51
37 -6.49 QP
14
720.0575 35.10 -2.11
32.99
37 -4.01 QP
15 1000.0000 29.30
2.67 31.97
37 -5.03 QP
Remarks:
21. All Readings below 1GHz are Quasi-Peak.
2. Emission Level= R Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. The
“
★
” means this data is worst-case Measurement level.