GESTEK
Lab
Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 4 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
2. SUMMARY OF TEST RESULTS
STANDARD
TEST ITEM
TEST
RESULT
REMARKS
Conducted emission
(Mode 1)
PASS
The worst emission frequency is 1.9563 MHz.
And minimum passing margin is –16.93 dB.
EN 55022
Class B
(1)AS/NZS CISPR 22
(for C-Tick)
Radiated emission
(Mode 1)
PASS
The worst emission frequency is 500.0025 MHz at
Vertical.
And minimum passing margin is –3.11 dB.
Height of antenna is 1 M.
Angle of turntable is 117
°
.
Harmonic Current
Emissions
PASS
EN 61000-3-2: 2000
EN 61000-3-3: 1995 +
A1: 2001
Voltage Fluctuation and
Flicker Measurement
PASS
With regards to the EN 61000-3-2, the PC must be
tested at full load in order to reach the assigned
current of the Power supply. With Dummy Load
Active Power > 75W
EN 55024
IEC 61000-4-2: 1995 +
A1: 1998 + A2:2000
Electrostatic
Discharge(ESD)
PASS
Contact discharge up to ±4kV .
Air discharge up to ±8kV .
EN 55024
IEC 61000-4-3: 2002 +
A1: 2002
RF field strength
Susceptibility
PASS
80-1000MHz
(1kHz sinewave with 80% Amplitude Modulation:
3V/m)
80, 120, 160, 230, 434, 460, 600, 863 and 900MHz:
3V/m
EN 55024
IEC 61000-4-4: 2004
Electrical Fast
Transients/Burst
PASS
±0.5kV, ±1.0kV (AC Input)
±0.5kV(LAN)
EN 55024
IEC 61000-4-5: 1995 +
A1: 2000
Surge
PASS
±0.5kV, ±1kV, ±2kV (AC Input)
EN 55024
IEC 61000-4-6: 2003 +
A1: 2004
Conducted Disturbance
Susceptibility
PASS
0.15-80MHz
(1kHz sinewave with 80% Amplitude Modulation: 3V)
0.2, 1, 7.1, 13.56, 21, 27.12 and 40.68MHz: 3V
Voltage short
Interruptions
>95% reduction, 5s
EN 55024
IEC 61000-4-11: 1994
+ A1: 2001
Voltage Dips
PASS
>95% reduction, 10 ms
30% reduction, 500 ms