5. RADIATED EMISSION MEASUREMENT
5.1 TEST EQUIPMENT
The following test equipments are used during the radiated emission tests:
Radiated emission measurement was performed at:
Site #1
Site #2
Site #3
Site #4
Item
Instrument
Manufacturer
Model
Serial No.
Last Cal. Date
1
Test Receiver
R & S
ESCS30
100035
06/10/04
2 Spectrum
Analyzer
HP
8542E
3520A00123/342
7A00118
07/21/04
3 Pre-Amplifier
HP
8447F OPT
H64
3113A04487 10/09/04
4 BILOG
Antenna SCHAFFNER CBL6112B
2580
11/30/04
5 RF
Cable
GTK
N/A GTK-E-A152-01
12/29/04
6 Open
Site
GTK
N/A
B2
11/23/04
Note: All equipment upon which need to calibrated are with calibration period of 1 year.
5.2 TEST METHOD
According to EN 55022: 1998 + A1: 2000 + A2: 2003
Radiated emission measurement was performed at the antenna to EUT distance of 10 meters.