GESTEK
Lab
Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 29 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
8. RF FIELD STRENGTH SUSCEPTIBILITY TEST
8.1 TEST EQUIPMENT
Item
Instrument
Manufacturer
Model
Serial No.
Last Cal. Date
1
Signal Generator
MARCONI 2030 3110196
06/29/04
2
Power Amplifier
A & R
150W1000
304198
N/A
3
Field Strength Meter
A & R
FM2000
16837
N/A
4 BILOG
Antenna
SCHAFFNER
CBL6111
1383
10/09/04
5 Chamber GesTek
B3
N/A 12/03/04
6
EMS Program
Software
GesTek
GTK-E-S001-01
GTK-E-S004-01
N/A N/A
Note: All measurement critical items of test instrumentation were within their calibration period of 1 year.
8.2 TEST METHOD
According to
EN 55024:1998 + A1: 2001 + A2: 2003
IEC 61000-4-3: 2002 + A1: 2002
8.3 BLOCK DIAGRAM OF TEST SETUP
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
EUT
Field Sensor
Non-Conducted
Table
80cm
3 m
1m
Ferrite Tile
Fully-Anechoic Chamber Equiped
with Ferrite Tile
Turn Table
Filter
Power
Amplifier
Signal Generator
Field Meter
Control
Computer
camera system
Camera
Monitor
Measurement Room
Antenna
mast
Power Supply
system
convertor
Load