GESTEK
Lab
Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 38 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
11. CONDUCTED DISTURBANCE SUSCEPTIBILITY TEST
11.1 TEST EQUIPMENT
Item
Instrument
Manufacturer
Model
Serial No.
Last Cal. Date
1 SIGNAL
GENERATOR
HP
8657A
3250A05164 11/01/04
2 Power
Amplifier
A & R
150A100A 25056
N/A
3
Dual Directional Couplor
A & R
DC-2600
20193
08/04/04
4 VOLTMETER BOONTON 9200C 361501AA
11/16/04
5 Injection
Clamp
Liithi
EM101
35260 08/20/04
6 ATTENUATOR
BNOS AT50-6-250 521926 08/12/04
Note: All equipment upon which need to calibrated are with calibration period of 1 year.
11.2 TEST METHOD
According to EN 55024:1998 + A1: 2001 + A2: 2003
IEC 61000-4-6: 2003 + A1: 2004
11.3 BLOCK DIAGRAM OF TEST SETUP
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
11.4 SEVERITY LEVELS
Test specification
Required Performance Criteria
: A
Level
: 1kHz sine wave with 80% Amplitude Modulation: 3V
Frequency range
: 0.15-80MHz
According to EN 55024:1998 + A1: 2001 + A2: 2003, an additional functional test shall be carried
out at the following frequencies: 0.2, 1., 7.1, 13.56, 21.0, 27.12 and 40.68MHz. (+/- 1%)
11.5 OPERATING CONDITIONS OF THE EUT
1. Setup the EUT and Test Equipment as shown on 11.3.
2. Power on the EUT. Acting performance checking program to allow EUT executing its usual
operation mode during test.
Aux
Equipment
EUT
Clamp or
CDN
Attenuator
Shield Room
Ground Reference
Plane
Non-Conducted Table
AC
Main
10cm
RF Signal
Generator
Power
Amplifier
10cm
CDN
AE
Dual Directional Couplor
VOLTMETER