Technical data of the device
14 / 157
DLT-V83 Operating Instructions V2.00
5.1.5.
Environmental conditions
DLT-V83 without integrated UPS
Operating temperature
-30 to +50 °C
Specification according to EN 60068-2-1/2
Storage temperature
-30 to +65 °C
Specification according to EN 60068-2-1/2
Relative humidity
10% to 90% at 40 °C relative humidity, noncondensing
Specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
DLT-V8310 and DLT-V8312:
−
Class 5M3 according to EN 60721-3-5
−
US Highway Truck according to MIL-STD 810F
DLT-V8315:
−
Class 5M2 according to EN 60721-3-5
−
US Highway Truck according to MIL-STD 810F
DLT-V83 with integrated UPS (optional)
Operating temperature
-10 to +50 °C
Charging temperature
0 to +45 °C (internal device temperature)
Storage temperature
-20 to +60 °C; specification according to EN 60068-2-1/2
Relative humidity
10% to 90% at 40 °C relative humidity, noncondensing;
specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
DLT-V8310 and DLT-V8312:
−
Class 5M3 according to EN 60721-3-5
−
US Highway Truck according to MIL-STD 810F
DLT-V8315:
−
Class 5M2 according to EN 60721-3-5,
−
US Highway Truck according to MIL-STD 810F