High-Pressure Lamps
The high-pressure lamps in the facials must be replaced,
whenever the useful lamp life as recommended by
manufacturer has run out. Or if lamp becomes defective.
The facials contain three high-pressure lamps.
When replacing high-pressure lamps always
use lamps of the same or compatible type. For
technical lamp data, see references on the type
label.
Disassembly
Make sure that the mains disconnection switch cuts off the
unit from the mains supply and that it is secured with lock
and key against accidential re-activation of power supply.
Disassemble the filter frames as described on page 33.
Loosen the two screws at the facial compartment.
Lift the facial slightly upward, so that you can unlock the
two lower brackets.
Put the facial onto the sunbed bench..
Disconnect the terminals “N“ and “LP“ and pull out the
litz wires and the blue neutral conductor.
Pull the high-pressure lamp downward out of the holder.
Pull out the litz wires with the high-pressure lamp out of
the lamp compartment.
CAUTION!
Never dispose of high—pressure
lamps with regular domestic
waste. Dispose of lamps in
an environmentally safe
way according to applicable
local/national standards and
regulations.
Dispose of defective or used up lamps.
Assembly
Put the new high-presure lamp into the holder.
Feed the litz wires backwards out of lamp compartment.
Connect one litz wire to the terminal marked as “LP“ .
Connect the other litz wire and the blue neutral conductor
to the terminal marked as “N“.
Lift the facial compartment into the top so that the
brackets can click in.
Tilt the facial compartment upwards.
Fasten with two screws.
Assemble the facial filter as described on page 33.