Body Cooling Fan
The body cooling fan must be disassembled, whenever:
•
the low-pressure lamps in the sunbed are replaced,
•
the sunbed plexi is replaced,
•
the top plexi is disassembled or
•
the whole unit is disassembled.
The body cooling fan must be replaced, when damaged.
Disassembly
Open the top.
Remove the thumb screw at the body cooling fan.
Push the body cooling fan into the direction as shown
above to disassemble the body cooling fan from of the
body cooling fan support.
Lift the body cooling fan upward and remove from body
cooling fan support.
Assembly
If you assemble a new body cooling fan, remove the
protective foil.
Put the body cooling fan in such a way to the body
cooling fan support that the air vents show towards the
sunbed.
Move the body cooling fan slightly forward until it locks.
Fasten the body cooling fan with the thumb nail to the
body cooling fan support.