2.2
Connection Overview- Panel Mount Unit
Figure 2.2: Panel Mount Connection Overview
CHASSIS
GROUND
Aux CT Input
Must use EXTERNAL CT Supplied
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
TB8
TB7
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
13
CT2
CT3
CT4
CT5
CT6
CT7
CT8
CT9
Optional For
Winding or
Load
TB6
Front Panel
DB-9
RS-232
1
2
3
4
5
6
7
8
9
GROUND
Rx
Tx
N/C
N/C
N/C
RTS
CTS
N/C
Optional
for Load
Only
TB7 & TB8 are
optional AC or DC
digital inputs. These
terminals will not be
present if the
additional input option
is not selected.
TB6 is for optional
extra CT inputs.
These terminals will
not be present if the
extra CT option is not
selected.
Pendant Rear
Panel RS232
(Optional)
GROUND
Rx
Tx
N/C
N/C
N/C
RTS
CTS
N/C
1
2
3
4
5
6
7
8
9
Power In
38 to 160VDC or 120VAC
TB3
Optional
Heater Option
Open @ 75 Deg F
CT1
1
2
3
4
1
2
3
4
5
6
TB5
A3
A2
A1
Analog
Outputs
Used for units with up to 3
isolated or non-isolated
analog outputs. TB5 is a 6
position plug-in style block.
Used for units with 4
isolated or non-isolated
analog outputs. TB5 is
an 8 position plug-in
style block.
Analog Output Options Note : Not present if the analog output option is not selected
1
2
3
4
5
6
A3
A2
A1
TB5
7
8
A4
1
2
3
4
5
6
TB5
A3
A2
A1
Rear Panel
Marked As
CT1-CT8
Shield
Connect to ground
REF
RTD
WHT
RED
BLK
Probe 2
TB2
COM
REF
TMP
COM
REF
TMP
1
2
3
4
5
6
7
8
9
10
11
12
COM
REF
TMP
Optional
Optional
REF
RTD
WHT
RED
BLK
Probe 1
REF
RTD
WHT
RED
BLK
Probe 3
If PROBE2 and/or PROBE3
channels are not ordered, no
connections will be made to
those terminals.
RS-485 For DNP3.0 or MODBUS
(Not Available if Fiber Optic Provided)
OUT 4
TB1A
OUT 3
OUT 2
OUT 1
1
2
3
4
5
6
7
8
9
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
2
3
4
1
IN1
IN2
OUT 6
OUT 5
NO
NC
COM
NO
NC
COM
1
2
3
4
5
6
7
8
9
TB1B
TB4
Digital Inputs and Relay Output Options
OUT 4
TB1A
OUT 3
OUT 2
OUT 1
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
2
3
4
1
OUT 6
OUT 5
NO
NC
COM
NO
NC
COM
TB1B
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
OUT 7
NO
NC
COM
OUT 8
NO
NC
COM
OUT 4
TB1A
OUT 3
OUT 2
OUT 1
1
2
3
4
5
6
7
8
9
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
2
3
4
1
IN1
IN2
OUT 6
OUT 5
NO
NC
COM
NO
NC
COM
1
2
3
4
5
6
7
8
9
TB1B
TB4
Tx
Rx
Multi-Mode Fiber Optic
DNP 3.0 or MODBUS Interface
(Not Available if RS-485 provided)
Used for units with up to 6 outputs & 2 digital inputs. I/O
terminals are labeled TB1A, TB1B and TB4. If only four
outputs are ordered, TB1B has no connections in the
OUT5 & 6 positions. If no inputs are ordered, there are
no connections to TB4.
Used for units with 8 outputs. I/O
terminals are labeled TB1A and TB1B.
5
6
7
NC
NO
COM
To Alarm
Summary of Contents for TTC-1000
Page 11: ...Warranty V6 230 20131017 x PAGE INTENTIONALLY BLANK ...
Page 41: ...V6 230 20131017 30 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 121: ...V6 230 20131017 110 PAGE INTENTIONALLY BLANK ...
Page 133: ...V6 230 20131017 122 PAGE INTENTIONALLY BLANK ...
Page 153: ...V6 230 20131017 142 PAGE INTENTIONALLY BLANK ...
Page 157: ...V6 230 20131017 146 PAGE INTENTIONALLY BLANK ...
Page 199: ...V6 230 20131017 188 PAGE INTENTIONALLY BLANK ...
Page 247: ...V6 230 20131017 236 PAGE INTENTIONALLY LEFT BLANK ...